On Thu, May 24, 2018 at 12:55 PM Steve Smith <[email protected]> wrote:

> IBM would like (for obvious reasons) to have an attribute that means
> "read-only", but for some reason, they've never managed to just say so.
> The standard definitions of RENT and REFR do not logically require
> read-only modules, but both are treated as if they do.
>

​It's too bad that RENT implies "read only". It makes complete sense that
REFR does. IIRC, back in the very old days, there was the "SVC transient"
area (2K or 4K) into which an type 3 SVC or one of the parts of a type 4
SVC was dynamically loaded. ​These modules were "refreshable" which I think
meant "MVS, you are allowed to refetch this module from disk and just
continue running it because I guarantee that the code & data areas in it
are not ever going to change".



>
> sas
>
>
-- 
Once a government places vague notions of public safety and security above
the preservation of freedom, a general loss of liberty is sure to follow.

GCS Griffin -- Pelaran Alliance -- TFS Guardian (book)


Maranatha! <><
John McKown

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,