If you were not aware, there is the DFSORT HOTLINE that can answer all types of
DFSORT questions
[email protected]
No PMR Needed. Questions answered.
Lizette
> -----Original Message-----
> From: IBM Mainframe Discussion List <[email protected]> On Behalf Of
> Jesse 1 Robinson
> Sent: Tuesday, June 05, 2018 9:32 AM
> To: [email protected]
> Subject: SORTLIB DD
>
> We have a DFSORT job that wolfs down enormous amounts of SORTWK space. It has
> been exceeding the DASD capacity on the system where it runs, so we advised
> the user to point SORTWK to tape instead of DASD. Now it fails with
>
> IEC130I SORTLIB DD STATEMENT MISSING
> IEF472I CIHM373 STEP010 CIHM373 - COMPLETION CODE - SYSTEM=000 USER=0063
>
> IBM doc indicates the need for SORTLIB with a 'tape sort'. We have no working
> example to share with the user. My question: what should DD SORTLIB point to?
> SMPE puts load modules into
>
> SYS1.SORTLIB
> SYS1.SICELINK
>
> Should the user specify only the first one or both? I hate to drag them into
> a sysprog guessing game.
>
> .
> .
> J.O.Skip Robinson
> Southern California Edison Company
> Electric Dragon Team Paddler
> SHARE MVS Program Co-Manager
> 323-715-0595 Mobile
> 626-543-6132 Office <===== NEW
> [email protected]<mailto:[email protected]>
>
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email to
> [email protected] with the message: INFO IBM-MAIN
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN