I set up the PDO logs to swap just like the SMF logs,
When HSM would swap from X to Y, Automation would kick off a IEBGENER to
copy it to a "permanent " dataset with the System & Time stamps as dataset
name and HSM/SMS Management Class to keep them around for 45 days with No
backup and 0 days on primary, and go directly to ML2 "Tape".
Jim
----- Original Message -----
From: "Gibney, Dave" <[email protected]>
Newsgroups: bit.listserv.ibm-main
To: <[email protected]>
Sent: Thursday, June 21, 2018 5:28 PM
Subject: Re: ARC0104I INVALID INITIALIZATION COMMAND
I have both LOG and PDA files. Never needed them, but the recomenadtion was
to have them active for IBM if needed.
DFHSM.LOGX
DFHSM.LOGY
DFHSM.PDOX
DFHSM.PDOY
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]]
On Behalf Of Ed Jaffe
Sent: Thursday, June 21, 2018 2:21 PM
To: [email protected]
Subject: Re: ARC0104I INVALID INITIALIZATION COMMAND
On 6/21/2018 2:17 PM, Gibney, Dave wrote:
> Looking some more and remembering. Do you have the HSM PDA
(Problem Determination AID) active? SETSYS PDS() and a couple datasets.
> I have a vague memory that this data can also be found using IPCS
> against
the active region. Or something.
Yes. I posted some of that data in response to Carmen Vitullo's query.
No help whatsoever...
--
Phoenix Software International
Edward E. Jaffe
831 Parkview Drive North
El Segundo, CA 90245
https://urldefense.proofpoint.com/v2/url?u=http-
3A__www.phoenixsoftware.com_&d=DwICaQ&c=C3yme8gMkxg_ihJNXS06Z
yWk4EJm8LdrrvxQb-Je7sw&r=u9g8rUevBoyCPAdo5sWE9w&m=CK-
VATOToJANlm1EWo7JHmZyFP9PKP4GGqo_6Zp6bWs&s=z41wqfPdr4WHaTk
DTu98jbwgbpdwIkUakMf_lDfl6s8&e=
--------------------------------------------------------------------------------
This e-mail message, including any attachments, appended messages and the
information contained therein, is for the sole use of the intended
recipient(s). If you are not an intended recipient or have otherwise
received
this email message in error, any use, dissemination, distribution,
review,
storage or copying of this e-mail message and the information contained
therein is strictly prohibited. If you are not an intended recipient,
please
contact the sender by reply e-mail and destroy all copies of this email
message and do not otherwise utilize or retain this email message or any
or
all of the information contained therein. Although this email message and
any
attachments or appended messages are believed to be free of any virus or
other defect that might affect any computer system into which it is
received
and opened, it is the responsibility of the recipient to ensure that it
is virus
free and no responsibility is accepted by the sender for any loss or
damage
arising in any way from its opening or use.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send
email to
[email protected] with the message: INFO IBM-MAIN
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN