> -----Original Message----- > From: IBM Mainframe Discussion List <[email protected]> On Behalf > Of Peter Hunkeler > Sent: Tuesday, July 03, 2018 10:10 PM > To: [email protected] > Subject: AW: Re: CPU Utilization > > >No, IEFUTL is called INSIDE an Address Space as often as specified in SMFPRMxx in > statement JWT. > > > .... and it would also be called when the CPU time used exceeds the time limit of the job or > step (TIME= parameter). But this means also that the exit is most never called.
But if you specify the desired time on the job statement (the OP said 30 min?), IEFUTL would get called and could take the desired action (extend for another 30 after generating some console message?). ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN