You need UPDATE access to IEASYMUP.symbolname in FACILITY.

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Sean Gleann
Sent: Monday, August 6, 2018 1:15 PM
To: [email protected]
Subject: 'Previous Day' system symbols (was: how to calculate previous day 
using REXX)

Very recently, I too went down the path of developing a REXX to figure out 
yesterday's date, and my solution pretty much matches ones that have been 
proposed in that mail-trail.

However, I wanted to go further. Having created a working REXX, I want to then 
automatically run it on a daily basis to set suitably-named system symbols with 
new values each day,

I've tracked down details regarding the IEASYMU2 program, but no matter what I 
do, the result is always RC288 (or '120'x). As far as I can see, this is caused 
by some sort of RACF restriction, but there's no diagnostic info appearing in 
the console log, so I don't know what to do to correct the situation.

Has anyone successfully used this program & would be prepared to share their 
experience, please?

Regards
Sean

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

.
הודעה זו נשלחה אליך מטעם חברה בקבוצת מלם תים וייתכן שהיא מוגנת תחת סודיות 
מסחרית. כל הצעה, התחייבות או מצג מטעם החברה, מחייבים מסמך נפרד וחתום על ידי 
מורשה החתימה של החברה. החברה רשאית לנטר כל תכתובת העוברת בשרתיה והיא לא תישא 
באחריות לכל נזק, ו/או אובדן, שיבוש או פגיעה במידע כלשהו שנגרם מסיבות של תקיפה 
חיצונית ו/או זדונית על הארגון.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to