our system rexx library is a library PDS-E, VB 255, I think the guy who set it 
up said FB 80 would not work,checking the fine manual he was correct, VB 255 is 
required 



Carmen Vitullo 

----- Original Message -----

From: "Carmen Vitullo" <[email protected]> 
To: [email protected] 
Sent: Thursday, August 23, 2018 9:53:47 AM 
Subject: Re: SYSREXX PDS size 

let me check, from what I recall sysrexx pds must be vb 255 :( 


Carmen Vitullo 

----- Original Message ----- 

From: "Tony Thigpen" <[email protected]> 
To: [email protected] 
Sent: Thursday, August 23, 2018 9:42:52 AM 
Subject: SYSREXX PDS size 

Our SYSREXX PDS is currently defined as VB 255. We had a system problem 
this week that one Sysprog thinks that the the VB 255 aggravated the 
problem and is insisting that we change it to FB 80. I disagree, but I 
thought I would though it out to the list for views. 

Views? 

-- 
Tony Thigpen 

---------------------------------------------------------------------- 
For IBM-MAIN subscribe / signoff / archive access instructions, 
send email to [email protected] with the message: INFO IBM-MAIN 


---------------------------------------------------------------------- 
For IBM-MAIN subscribe / signoff / archive access instructions, 
send email to [email protected] with the message: INFO IBM-MAIN 


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to