With a lot of off-list help, I finally got this working. Appears that I skipped 
way too many SHARE What's New in SDSF sessions over the past few years. Here's 
a summary of how to get it working in z/OS 2.1+.

-- Displaying inline SYSIN will work only on the ST(atus) display, not 
O(output) or H(old) display.   
-- If it's not working for you, issue command SET SCREEN   
-- Select 1.   Basic settings and tabular panels  
-- Select       Display the action bar        1  1. Yes  
-- On the action bar, click Options   
-- Select 2. Browse and Print...   
-- Select 2  Change include SYSIN to ON (if this OFF, then it's already ON)  
-- Go back to ST display  

At this point you can issue command INPUT ON. When you select a job on the ST 
screen with '?', you will see all JES2 data sets including inline SYSIN. 

Special thanks to Sri Kolusu and Tom Dien. 

.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler 
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-543-6132 Office ⇐=== NEW
[email protected]


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Paul Gilmartin
Sent: Tuesday, August 28, 2018 3:25 PM
To: [email protected]
Subject: (External):Re: SDSF INPUT ON/OFF

On Tue, 28 Aug 2018 21:01:37 +0000, Jesse 1 Robinson wrote:

>A colleague noticed that SDSF INPUT ON is not showing a SYSIN DD * data set. 
>It's supposed to, right? OTOH SJ for the job shows everything including inline 
>input. This is z/OS 2.3.
> 
"?" display, not "O" or "H", right?

My observation has been that it shows SYSINs but does not identify them by 
STEPNAME/DDNAME until they've been opened.  I suppose there's a reason, but 
hardly a good one.