> If I take the value for July 1st, 2015 from the PoP table and > subtract the equivalent of one second I understand this is the TOD > value for June 30 23:59:60. Am I mixing up things?
The TOD clock values given in the PoPs correspond to a UTC time of 00:00:00 on the specified date assuming leap seconds are used. The TOD clock value CF2D 54B4 FBA8 0000 for July 1st, 2015 assuming 26 leap seconds are specified is correct: IP LTOD CF2D54B4FBA80000 returns 07/01/2015 00:00:26.000000 STCK X'CF2D54B4 FBA80000' The PoP has been now updated with the leaps second value of 27 which occurred January 1st, 2017 Regards, George Kozakos z/OS Software Service, Level 2 Supervisor ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN