> If I take the value for July 1st, 2015 from the PoP table and
> subtract the equivalent of one second I understand this is the TOD
> value for June 30 23:59:60. Am I mixing up things?

The TOD clock values given in the PoPs correspond to a UTC time of
00:00:00 on the specified date assuming leap seconds are used.

The TOD clock value CF2D 54B4 FBA8 0000 for July 1st, 2015 assuming
26 leap seconds are specified is correct:

IP LTOD CF2D54B4FBA80000 returns
07/01/2015 00:00:26.000000 STCK   X'CF2D54B4 FBA80000'

The PoP has been now updated with the leaps second value of 27 which
occurred January 1st, 2017

Regards, George Kozakos
z/OS Software Service, Level 2 Supervisor


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to