Hello ,

I run tapemap and able to list all volume backup dataset on tape.

/SYSPRINT DD  SYSOUT=*

//DASD1    DD  UNIT=3390,VOL=SER=REST01,DISP=OLD

//TAPE     DD UNIT=359D,DISP=SHR,DSN=BKUP.PROH19.TP <http://bkup.proh19.tp/>
,LABEL=(1,BLP),

//            VOL=SER=(PROD01)


 In above DD stmt, we are trying to restore BKUP.PROH19.TP using BLP
option, so, there is no use of putting sequence number of this dataset on
tape. I can always use 1 in this case.


Please correct, if I my understanding is wrong.

On Wed, Sep 19, 2018 at 12:52 PM Elardus Engelbrecht <
[email protected]> wrote:

> venkat kulkarni wrote:
>
> >We already tried with option BLP and receive below error.
>
> Please post the full DD statement with that BLP.
>
>
> >ADR389E (001)-BKIOR(01), INVALID INPUT ON DDNAME TAPE, INPUT DATA SET NOT
> > PRODUCED BY DFDSS OR DFSMSDSS
> >ADR389E (001)-TDDS (07), INVALID INPUT ON DDNAME TAPE, INPUT DATA SET NOT
> >PRODUCED BY DFDSS OR DFSMSDSS
>
> I believe you are picking up an incorrect/wrong dataset on your tape.
>
> Run a Tapemap on that volser. What do you see there?
>
>
> >Yes,  TEST01 to PROD01 copy was 100% successful.
>
> Thanks. One worry eliminated.
>
> Groete / Greetings
> Elardus Engelbrecht
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to