Hello , I run tapemap and able to list all volume backup dataset on tape.
/SYSPRINT DD SYSOUT=* //DASD1 DD UNIT=3390,VOL=SER=REST01,DISP=OLD //TAPE DD UNIT=359D,DISP=SHR,DSN=BKUP.PROH19.TP <http://bkup.proh19.tp/> ,LABEL=(1,BLP), // VOL=SER=(PROD01) In above DD stmt, we are trying to restore BKUP.PROH19.TP using BLP option, so, there is no use of putting sequence number of this dataset on tape. I can always use 1 in this case. Please correct, if I my understanding is wrong. On Wed, Sep 19, 2018 at 12:52 PM Elardus Engelbrecht < [email protected]> wrote: > venkat kulkarni wrote: > > >We already tried with option BLP and receive below error. > > Please post the full DD statement with that BLP. > > > >ADR389E (001)-BKIOR(01), INVALID INPUT ON DDNAME TAPE, INPUT DATA SET NOT > > PRODUCED BY DFDSS OR DFSMSDSS > >ADR389E (001)-TDDS (07), INVALID INPUT ON DDNAME TAPE, INPUT DATA SET NOT > >PRODUCED BY DFDSS OR DFSMSDSS > > I believe you are picking up an incorrect/wrong dataset on your tape. > > Run a Tapemap on that volser. What do you see there? > > > >Yes, TEST01 to PROD01 copy was 100% successful. > > Thanks. One worry eliminated. > > Groete / Greetings > Elardus Engelbrecht > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN