It probably includes a compress

> -----Original Message-----
> From: IBM Mainframe Discussion List <[email protected]> On
> Behalf Of Lizette Koehler
> Sent: Monday, October 01, 2018 7:53 AM
> To: [email protected]
> Subject: Re: S106 abends after copying into LINKLIST
> 
> We use a process from the cbttape.org called PDSCLEAN.  It can clear out PDS
> or PDS/E but same caveats exits.  Shut down the task before cleaning the
> directories.
> 
> 
> Lizette
> 
> 
> > -----Original Message-----
> > From: IBM Mainframe Discussion List <[email protected]> On
> > Behalf Of Barkow, Eileen
> > Sent: Monday, October 01, 2018 7:48 AM
> > To: [email protected]
> > Subject: Re: S106 abends after copying into LINKLIST
> >
> > Thanks Lizette.
> >
> > The dataset is was emptied/copied in a different lpar than where it is used.
> > But as was explained, the pds directory got altered by the empty
> > member procedure and no LLA REFRESH was done.
> >
> > -----Original Message-----
> > From: IBM Mainframe Discussion List [mailto:IBM-
> [email protected]]
> > On Behalf Of Lizette Koehler
> > Sent: Monday, October 01, 2018 10:45 AM
> > To: [email protected]
> > Subject: Re: S106 abends after copying into LINKLIST
> >
> > What the Dataset where the modules were staged shared among Plexes or
> > are just allocated to one Plex (but shared among any members in that
> > Plex)
> >
> > PDS/E datasets can be very touchy.
> >
> > Did you find an S213 abends on the libraries prior to the S106?
> >
> > Check the first module indicated in the first S106.  Did it have an
> > I/O errors when you browse it?
> >
> > Can you do an IEBCOPY of the PDS to a new one and see if IEBCOPY shows
> > any I/O Errors
> >
> > Can you do a IEBPDSE Copy of the PDS/E to a new one and see if there
> > are any I/O errors?
> >
> > https://urldefense.proofpoint.com/v2/url?u=https-
> 3A__www.ibm.com_support_knowledgecenter_en_SSLTBW-
> 5F2.1.0_com.ibm.zos.v2r1&d=DwICAg&c=C3yme8gMkxg_ihJNXS06ZyWk4EJ
> m8LdrrvxQb-
> Je7sw&r=u9g8rUevBoyCPAdo5sWE9w&m=SSH0jhO6X7PmFrTFoUlzrgHfxMh
> w78-yYm11eiLkzS8&s=Q2WQ12FSAwlkrSDKWIWKwTcy4-
> 1tlVJA0mEoO2gowpY&e=.
> > ida
> > u100/pdse.htm
> >
> >
> > Lizette
> >
> >
> > > -----Original Message-----
> > > From: IBM Mainframe Discussion List <[email protected]>
> On
> > > Behalf Of Barkow, Eileen
> > > Sent: Monday, October 01, 2018 7:10 AM
> > > To: [email protected]
> > > Subject: S106 abends after copying into LINKLIST
> > >
> > > Hi MVS gurus.
> > >  Perhaps someone can offer a plausible explanation for this, so that
> > > the MVS group will stop blaming the CICS group for the problem.
> > >
> > > Last friday morning we copied new CICS LINKLIST/LPA modules into the
> > > existing LINKLIST/LPA loadlibs in use (a rather new scenario in use
> > > here - we used to use alternative datasets), in anticipation of an
> > > IPL to be done sunday morning.
> > > anyway, around 6pm friday evening, an I/O error occured in linklist
> > > and other jobs started abending with S106 abends.
> > > the linklist library was not allocated with secondary extents and
> > > there was no LLA refresh issued during the day. I cannot find
> > > anything like this situation occurring on IBMLINK and we have no
> > > dump of the
> > original failure.
> > >
> > > Does anyone have any idea of what could have caused the I/O error.
> > > both the input and output datasets have a max blksize of 32760.
> > >
> > > IEW4009I FETCH FAILED FOR MODULE DFHXCPRX FROM DDNAME -
> LNKLST-
> > > BECAUSE OF AN I/O ERROR.
> > > IEW4005I FETCH FOR MODULE DFHXCPRX FROM DDNAME -LNKLST-
> FAILED
> > > BECAUSE IEWFETCH ISSUED RC 0F AND REASON 40 CSV031I LIBRARY
> ACCESS
> > > FAILED FOR MODULE DFHXCPRX, RETURN CODE 24, REASON CODE
> 26080021,
> > > DDNAME *LNKLST*
> > >
> > >
> > >
> > >
> > >
> > >   ________________________________
> > >
> > > This e-mail, including any attachments, may be confidential,
> > > privileged or otherwise legally protected. It is intended only for
> > > the addressee. If you received this e-mail in error or from someone
> > > who was not authorized to send it to you, do not disseminate, copy
> > > or otherwise use this e-mail or its attachments. Please notify the
> > > sender immediately by reply e-mail and delete the e-mail from your
> system.
> > >
> > >
> > > --------------------------------------------------------------------
> > > -- For IBM-MAIN subscribe / signoff / archive access instructions,
> > > send email to [email protected] with the message: INFO
> > > IBM-MAIN
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions, send
> > email to [email protected] with the message: INFO IBM-MAIN
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions, send
> > email to [email protected] with the message: INFO IBM-MAIN
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email to
> [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to