Then you should go to SHARE and hear David Hayes. GSA auditor (just retired)
and WAY mainframe competent.

https://events.share.org/Summer2017/Public/SpeakerDetails.aspx?FromPage=Sess
ions.aspx&ContactID=4443 

Charles


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of Allan Staller
Sent: Tuesday, October 23, 2018 8:30 AM
To: [email protected]
Subject: Re: get ECSA key 7 storage under CICS

I have not seen a competent auditor for the mainframe in about 30 years. <G>

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of
Seymour J Metz
Sent: Monday, October 22, 2018 3:59 PM
To: [email protected]
Subject: Re: get ECSA key 7 storage under CICS

Aside from that, Mrs. Lincoln, how was the play? Any competent auditor who
saw that would slap you down.


--
Shmuel (Seymour J.) Metz
https://apac01.safelinks.protection.outlook.com/?url=http:%2F%2Fmason.gmu.ed
u%2F~smetz3&amp;data=02%7C01%7Callan.staller%40HCL.COM%7C0b405e2de86547e79c3
108d63861487a%7C189de737c93a4f5a8b686f4ca9941912%7C0%7C0%7C63675838784907309
1&amp;sdata=9AJSiwhwXFuvNY6QicauGK8yUf6JNs52fsoHfLFnixY%3D&amp;reserved=0

________________________________________
From: IBM Mainframe Discussion List <[email protected]> on behalf of
Barkow, Eileen <[email protected]>
Sent: Thursday, October 18, 2018 9:55 AM
To: [email protected]
Subject: Re: get ECSA key 7 storage under CICS

The   SVC code just sets the JSCBAUTH bit on for a few nanoseconds while the
user code runs and then sets if off  in response to another SVC call to do
so.
I do not run it any more but it really came in handy and did not cause any
problems.

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of Jousma, David
Sent: Thursday, October 18, 2018 9:50 AM
To: [email protected]
Subject: Re: get ECSA key 7 storage under CICS

Eileen,  that code sounds suspiciously like a huge security vulnerability?
Am I missing something?

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of
Barkow, Eileen
Sent: Thursday, October 18, 2018 9:46 AM
To: [email protected]
Subject: Re: get ECSA key 7 storage under CICS

**CAUTION EXTERNAL EMAIL**

**DO NOT open attachments or click on links from unknown senders or
unexpected emails**

I actually have run a few CICS programs in supervisor state using an old SVC
routine that LRS used to provide - You just pass it the address of the code
to run and it sets the JSCBAUTH bit on so that the code runs in supervisor
state/key 0.
I needed this in order to issue MVS commands directly from CICS, like VTAM
commands to vary devices INACT and START commands for various things.
I still have the SVC code if anyone wants it.

The problem with CICS has always been that it sets the JSCBAUTH  bit off
after initialization so that APF authorized programs cannot run.



-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of Binyamin Dissen
Sent: Thursday, October 18, 2018 7:13 AM
To: [email protected]
Subject: Re: get ECSA key 7 storage under CICS

You need to be supervisor state to do this. Using CICS just because it is
easier is a wrong decision.

But if you are sold on using CICS, you would need to write a SVC routine to
actually do the work and have your transaction supply a CICS area as a
buffer and the SVC routine will do the IFI work and return the record.

On Thu, 18 Oct 2018 05:08:36 -0500 Wang Rong <[email protected]> wrote:

:>Hi Binyamin,
:>
:>     Many thanks to your quick replay.
:>     I'm trying to capture/send DB2 log record using IFI call. The storage
requirement is ECSA key 7 storage: "The return area for monitor programs
that issue IFCID 0306 requests must reside either in ECSA key 7 storage or
in the 64-bit common key 7 storage area above the 2-GB bar" (from IBM book).
:>     I prefer to use CICS because it's easy programming.
:>
:>

--
Binyamin Dissen <[email protected]>
https://apac01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fsecure-web
.cisco.com%2F17INyMZEastU6hSb1nPkrFO5WKlQKoQHh5RHA_eDpmC-JKHpqfo1pdcQPx1lBFW
Y38oUG_MSezBJo_ZGBYAyFRO_IKqfP4IRZS1d6FIJi_Y0-kWSOvyAypury2i0w2Wf8xkdf0yB04O
Erkistjxhfn3UKwgZhh0y3ky-8dwwqwC_1ZtY7o-5nRowJKFIn3SJi1PynOfw3X0RtH6X_M0tZJU
-czSyZZ7YcGemmbhYfF9huScFGcmjDbnSzBjRmkOuHkFyaUQDgAn8Tkyih0WD3IPR5AVszxzJDSN
VFEq-hZgbGKfSe6kUgAG9Eivs4-3ddmc2-gBAG_3Ky9LvRGmxAbGLdalRGDzmFS9TyXd0Oe75EKt
1IiVriJgZXoe7fx0FvFXaRpFRDrjs_kE0eFeA0sdjA6Cdo0xC7MI87Uce2ko3ep4amA0wihNOp4D
Qx7jL1%2Fhttp%253A%252F%252Fwww.dissensoftware.com&amp;data=02%7C01%7Callan.
staller%40HCL.COM%7C0b405e2de86547e79c3108d63861487a%7C189de737c93a4f5a8b686
f4ca9941912%7C0%7C0%7C636758387849073091&amp;sdata=b6hBfMpT9jUHDeX9lTP2p6R73
VXJliHJndToV5bFADI%3D&amp;reserved=0

Director, Dissen Software, Bar & Grill - Israel


Should you use the mailblocks package and expect a response from me, you
should preauthorize the dissensoftware.com domain.

I very rarely bother responding to challenge/response systems, especially
those from irresponsible companies.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email
to [email protected] with the message: INFO IBM-MAIN

________________________________

This e-mail, including any attachments, may be confidential, privileged or
otherwise legally protected. It is intended only for the addressee. If you
received this e-mail in error or from someone who was not authorized to send
it to you, do not disseminate, copy or otherwise use this e-mail or its
attachments. Please notify the sender immediately by reply e-mail and delete
the e-mail from your system.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email
to [email protected] with the message: INFO IBM-MAIN **CAUTION
EXTERNAL EMAIL**

**DO NOT open attachments or click on links from unknown senders or
unexpected emails**


This e-mail transmission contains information that is confidential and may
be privileged.   It is intended only for the addressee(s) named above. If
you receive this e-mail in error, please do not read, copy or disseminate it
in any manner. If you are not the intended recipient, any disclosure,
copying, distribution or use of the contents of this information is
prohibited. Please reply to the message immediately by informing the sender
that the message was misdirected. After replying, please erase it from your
computer system. Your assistance in correcting this error is appreciated.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email
to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email
to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email
to [email protected] with the message: INFO IBM-MAIN
::DISCLAIMER::
----------------------------------------------------------------------------
----------------------------------------------------------------------------
----------------------------------------------------------------------------
--------------------------------------------------
The contents of this e-mail and any attachment(s) are confidential and
intended for the named recipient(s) only. E-mail transmission is not
guaranteed to be secure or error-free as information could be intercepted,
corrupted, lost, destroyed, arrive late or incomplete, or may contain
viruses in transmission. The e mail and its contents (with or without
referred errors) shall therefore not attach any liability on the originator
or HCL or its affiliates. Views or opinions, if any, presented in this email
are solely those of the author and may not necessarily reflect the views or
opinions of HCL or its affiliates. Any form of reproduction, dissemination,
copying, disclosure, modification, distribution and / or publication of this
message without the prior written consent of authorized representative of
HCL is strictly prohibited. If you have received this email in error please
delete it and notify the sender immediately. Before opening any email and/or
attachments, please check them for viruses and other defects.
----------------------------------------------------------------------------
----------------------------------------------------------------------------
----------------------------------------------------------------------------
--------------------------------------------------

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to