I use Name Token Pairs for passing dataYou may want to consider using the Sub 
System Interface (SSI) GET/PUT to anchor a control block in common.

---------- Original Message ----------
From: Robin Atwood <[email protected]>
To: [email protected]
Subject: ASCRE init module (again)
Date: Wed, 9 Jan 2019 18:37:02 +0700

In my init module I now want to obtain storage and set up a control block
and pass the address to the main program. Where is a good place to stash
this? I suppose I could create an N/T pair but this seems a bit cumbersome
just to pass a single address within an address space. There is the TCBUSER
field in the top-level TCB (IEAVAR00) but that's a bit scary. I create an
ACEE and that has a field ACEEAPTR which is reserved for the application, so
that is a possibility. What do other people do? Am I missing something
blindingly obvious?!

Thanks
Robin

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to