This is the 2GB LPAR on the IBM Remote Development program. I'm guessing
that's how it's rolled out to folks like us.

I have had some success on another customer site, but I can't really post
about it here because it's <secret>.

And the third customer site gets the same S106 abend.

This same problem has been kicking around since 2009, I found an old
reference today relating to CICS 3.2.


On Sat, Jan 19, 2019 at 7:42 AM Jesse 1 Robinson <[email protected]>
wrote:

> Understood. I just remember Elpida and company saying that a lot of
> general problems stemmed from a too-small LPAR size. General observation,
> not an explanation for the current case.
>
> .
> .
> J.O.Skip Robinson
> Southern California Edison Company
> Electric Dragon Team Paddler
> SHARE MVS Program Co-Manager
> 323-715-0595 Mobile
> 626-543-6132 Office ⇐=== NEW
> [email protected]
>
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Ed Jaffe
> Sent: Friday, January 18, 2019 11:30 AM
> To: [email protected]
> Subject: (External):Re: Abend 106 (was Generic query on Region allocation
> failure)
>
> On 1/18/2019 11:02 AM, Jesse 1 Robinson wrote:
> > Even Peter Relson did not comment on this, but I gotta say it: 2 GB LPAR
> is too small.
>
>
> But, just to be clear, increasing the central storage available to this
> LPAR will *NOT* solve this issue. The 24-bit private area will continue to
> be 8M.
>
>
> --
> Phoenix Software International
> Edward E. Jaffe
> 831 Parkview Drive North
> El Segundo, CA 90245
> https://www.phoenixsoftware.com/
>
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>


-- 
Wayne V. Bickerdike

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to