You did not specify which compiler version or if the dump is from batch or CICS, but... This link is CICS orientated and was published in 2009, so it may not apply to the "newer" compilers: http://www-01.ibm.com/support/docview.wss?uid=swg27017236 . I think the key in either environment is to find the LE CAA. If the LE CAA is in the dump, slide 8 has the pointer links to the COBOL TGT and the offset to WS length.

Alan

Lizette Koehler wrote:
Yep, another question

Is there a way in a SVC Dump or SYSUDUMP to determine the size of the working
storage section?

My original issue looks to be caused by two things,
     1)  The working storage size increased
     2)  There is one 24bit module linked with all the 31bit modules, thereby
forcing it below the line

Any guidance appreciated



Lizette Koehler
statistics: A precise and logical method for stating a half-truth inaccurately

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to