So running an SMP/E CLEANUP against the target zone should delete that (I assume
the function sysmod is accepted).  I guess IBM should do that on whatever zone 
is 
used to merge OGL/370 (or whatever their process is) into the z/OS SMP/E zones
delivered with a z/OS ServerPac also. 

As far as your hesitation to drop it, I feel your pain. :-)  Still so many of 
these
printing related program products lying around my clients'  environments 
(OGL/370,
various fonts etc.) that everyone is afraid to drop and I think they way they 
are 
used doesn't lend software like TADz to track their usage.  

Best Regards,

Mark
--
Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS
ITIL v3 Foundation Certified
mailto:[email protected]
Mark's MVS Utilities: http://www.mzelden.com/mvsutil.html
Systems Programming expert at http://search390.techtarget.com/ateExperts/



On Wed, 8 May 2019 21:28:20 +0000, Jesse 1 Robinson <[email protected]> 
wrote:

>There's a sysmod entry for UQ13184 in the target that shows SUP'D by FMID 
>HVRL100. It doesn't make sense but without this nonsense, SMPMTS would be 
>empty. It's one of those products we keep ordering because no one still here 
>is confident in dropping it.  
>
>.
>.
>J.O.Skip Robinson
>Southern California Edison Company
>Electric Dragon Team Paddler 
>SHARE MVS Program Co-Manager
>323-715-0595 Mobile
>626-543-6132 Office ⇐=== NEW
>[email protected]
>
>-----Original Message-----
>From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
>Mark Zelden
>Sent: Wednesday, May 8, 2019 1:09 PM
>To: [email protected]
>Subject: (External):Re: MODGEN vs AMODGEN
>
>OGL/370 is not a base z/OS component it is an old program product. I think my
>client dropped it finally at z/OS 2.1.   
>
>But being that it is ancient (25 yrs old?), why wouldn't all the maintenance 
>come accepted with a ServerPac order?  
>
>Best Regards,
>
>Mark
>--
>Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS ITIL v3 
>Foundation Certified mailto:[email protected] Mark's MVS Utilities: 
>http://www.mzelden.com/mvsutil.html
>Systems Programming expert at http://search390.techtarget.com/ateExperts/
>
>
>
>On Wed, 8 May 2019 19:06:51 +0000, sesse 1 Robinson <[email protected]> 
>wrote:
>
>>Our SMPMTS (for 2.3) contains two macros for
>>
>>HVRL1 0                           
>>OVERLAY GENERATION LANGUAGE, BASE
>>
>>They look really old, but we start each release with a fresh SMPE 
>>environment, so no carryover is possible.   
>>
>>.
>>.
>>J.O.Skip Robinson
>>Southern California Edison Company
>>Electric Dragon Team Paddler
>>SHARE MVS Program Co-Manager
>>323-715-0595 Mobile
>>626-543-6132 Office ⇐=== NEW
>>[email protected]
>>
>>-----Original Message-----
>>From: IBM Mainframe Discussion List <[email protected]> On 
>>Behalf Of Mark Zelden
>>Sent: Wednesday, May 8, 2019 11:42 AM
>>To: [email protected]
>>Subject: (External):Re: MODGEN vs AMODGEN
>>
>>On Wed, 8 May 2019 17:50:20 +0000, Seymour J Metz <[email protected]> wrote:
>>
>>>> To my understanding they are just a target lib and distribution library.
>>>
>>>Yes, which is why they are not 9nterchangable. If you want macros from the 
>>>running system, use MODGEN  and MTS; if you want only the accepted service, 
>>>use AMODGEN.
>>>
>>
>>SMPMTS seems a thing of the ptst for z/OS.  Are there any base z/OS 
>>components that don't have a target library now?  Any optional ones?  My 
>>SMPMTS is empty for both
>>z/OS 2.2 and z/OS 2.3.   I accept maintenance one year behind apply and I'm 
>>at RSU1812
>>for both z/OS 2.2 (which a few systems are at) and z/OS 2.3. 
>>
>>
>>Best Regards,
>>
>>Mark
>>--
>>Mark Zelden - Zelden Consuiting Services - z/OS, OS/390 and MVS ITIL v3 
>>Foundation Certified mailto:[email protected] Mark's MVS Utilities: 
>>http://www.mzelden.com/mvsutil.html
>>Systems Programming expert at 
>>http://search390.techtarget.com/ateExperts/
>
>
>----------------------------------------------------------------------
>For IBM-MAIN subscribe / signoff / archive access instructions,
>send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to