PARMLIB(IEASYSxx) LOGREC parameter
On Wed, 15 May 2019 at 15:35, Gadi Ben-Avi <[email protected]> wrote: > Thanks > Where do I define the name of the logstream for LOGREC? > Gadi > > -----Original Message----- > From: IBM Mainframe Discussion List <[email protected]> On Behalf > Of Mike Shorkend > Sent: Wednesday, May 15, 2019 3:29 PM > To: [email protected] > Subject: Re: Logrec Logstream name > > Gadi > If you do not have a coupling facility, them the logstream has to be DASD- > only and can not be shared between LPARS. See here: > > > https://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.3.0/com.ibm.zos.v2r3.ieag200/cfod.htm > > You will need to use a unique name for each logstream. You could use the > &SYSNAME. system symbol as part of the name to make things easier. > > HTH > > Mike > > > > > > On Wed, 15 May 2019 at 14:57, Gadi Ben-Avi <[email protected]> wrote: > > > Hi, > > We have a basic sysplex with two members. > > There is no coupling facility. > > > > > > 1. Is it possible to use the same logrec logstream > > (SYSPLEX.LOGREC.ALLRECS) for both systems. > > > > 2. If not, how do I specify different a logstream for each system? > > > > We are using z/OS v2.3 > > > > Gadi > > > > > > ---------------------------------------------------------------------- > > For IBM-MAIN subscribe / signoff / archive access instructions, send > > email to [email protected] with the message: INFO IBM-MAIN > > > > > -- > Mike Shorkend > [email protected] > www.shorkend.com > Tel: +972524208743 > Fax: +97239772196 > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send email > to [email protected] with the message: INFO IBM-MAIN > -- Mike Shorkend [email protected] www.shorkend.com Tel: +972524208743 Fax: +97239772196 ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN