On Tue, Jun 25, 2019 at 06:14 Giliad Wilf <
[email protected]> wrote:

> On Tue, 25 Jun 2019 15:37:11 +1000, Wayne Bickerdike <[email protected]>
> wrote:
>
> >Jake,
> >
> >your DD statemtnt looks wrong:
> >
> >Try:
> >
> >//SYSUT1 DD
> >DSN=A,LABEL=(,BLP,EXPDT=98000),UNIT=VTAPE,VOL=SER=P098878,DISP=(OLD,PASS)
> >
> >On Mon, Jun 24, 2019 at 2:04 PM Jake Anderson <[email protected]>
> >wrote:
> >
> >> Hi
> >>
> >> I am running this JCL to obtain information about a virtual tape.
> >>
> >> //JOBCARD
> >> // STEP EXEC PGM=TAPEMAP
> >> //SYSPRINT DD SYSOUT=*
> >> //SYSPRINT2 DD SYSOUT=*
> >> //SYSUT1 DD
> >> LABEL=(,BLP,EXPDT=98000),UNIT=VTAPE,VOL=SER=P098878,DISP=(OLD,PASS)
> >>
> >> The error I get is
> >>
> >> ** DEVICE TYPE WAS NOT SPECIFIED
> >> ** ERROR DETECTED BY PARAMETER CONVERTER, PROCESSING ABORTED
> >>
> >> Is there anything missed out in my JCL as I have specified UNIT .
> >>
> >> Jake
> >>
> >> ----------------------------------------------------------------------
> >> For IBM-MAIN subscribe / signoff / archive access instructions,
> >> send email to [email protected] with the message: INFO IBM-MAIN
> >>
> >
> >
> >--
> >Wayne V. Bickerdike
>
>
> Since label processing is being bypassed, DSN can be any syntactically
> valid name, but why is volser 7-char long?
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to