I searched and found "ISPT037 Library format error - Invalid record: Table=aaaaaaaa TTRN=bbbbbbbb Offset=cccccccc." So if you still have the message, you could perhaps estimate where the error is in the member.
Packed? Back in the day, when I was a sysprog, we didn't pack tables. I have no idea whether that still applies. If it does, it would seem worth asking how it got packed. EDIT with PACK ON, maybe? :-) Ruz On Thu, 10 Oct 2019, 11:11 Bill Giannelli, <[email protected]> wrote: > I am getting an ISPT037 error. A search on this error says to "unpack the > ISPF table" with ISPF copy/move. I copied the member involved (ISPSPROF) > and moved it back. But I still get the same error. How do I get around this > error? > thanks > Bill > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN