The current CBT 183 has a fix for this. See SWAREQ22 (it was z/OS 2.2 where the breaking change was introduced.) It works on pre-2.2 as well, so there's no need to hold on to the original SWAREQ.
In article <[email protected]> you wrote: > Bad form to reply to myself, but I should have added this. > This gave me a hint: > https://www.ibm.com/support/pages/abend0c4-or-other-problems-retrieving-dataset-names-cobol > This gave me the answer: > https://www-01.ibm.com/support/docview.wss?uid=swg1PI58751 > We're moving to z/OS 2.3 which was the source of the environment change. > best regards, > Peter > On Thu, 17 Oct 2019 22:34:44 -0500, Peter Bishop <[email protected]> wrote: > >Hi, > > > >in case anyone else is having failures using the old SWAREQ REXX that is > >floating around (originally from Gilbert Saint Flour), in our case as part > >of a REXX that compares catalogues via the IGGCSI00 program and various > >other methods, you will need to change your job class to SWA=BELOW to get it > >to work. > > > >After I did that, the mysterious errors relating to rubbish dataset names > >that SWAREQ was returning vanished, and normal processing resumed. > > > >Hope this saves some time for others. > > > >best regards, > >Peter -- Don Poitras - SAS Development - SAS Institute Inc. - SAS Campus Drive [email protected] (919) 531-5637 Cary, NC 27513 ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN