the error description indicates that 1.13 is too downlevel for the
aggregate version:

Description: New version aggregates cannot be processed on this system.

Action: If this is a primary mount, re-issue the mount on a system that
supports higher version aggregates. If this is a catchup mount, no action is
needed. z/OS UNIX will function ship operations to the z/OS UNIX owner.
--
Artificial Intelligence is no match for Natural Stupidity
  - Unknown


On Wed, Dec 18, 2019 at 7:35 AM Allan Staller <[email protected]> wrote:

> TSO BPXMTEXT EF096A32 will tell you exactly why the file system was not
> mounted.
> I haven't looked, but IIRC error code 79 indicates some sort of "file not
> found" (???) error.
>
> HTH,
>
>
>
> -----Original Message-----
> From: IBM Mainframe Discussion List <[email protected]> On Behalf
> Of R Hey
> Sent: Tuesday, December 17, 2019 5:59 PM
> To: [email protected]
> Subject: Re: ZOS 1.13 2.2 2.3 in the same sysplex
>
> I had build a new plex on zos 1.13, new CF, XCF CDS, SMS, RMM, RACF, Mcat,
> etc, with only 1 LPAR in it.
> IPL’d the same LPAR with zos 22 sysres/Mcat: OK IPL’d the same LPAR with
> zos 23 sysres/Mcat: OK IPL’d the same LPAR with zos 22 sysres/Mcat: OK
>
> IPL’d the same LPAR with zos 1.13 sysres/Mcat: NOT OK  !
> Failed to mount plex root ZFS, ETC, VAR, … BPXF002I  code 79 reason
> EF096A32
>
> Created new ZFS, IPL 1.13 : OK
>
> cheers
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email
> to [email protected] with the message: INFO IBM-MAIN
> ::DISCLAIMER::
> ________________________________
> The contents of this e-mail and any attachment(s) are confidential and
> intended for the named recipient(s) only. E-mail transmission is not
> guaranteed to be secure or error-free as information could be intercepted,
> corrupted, lost, destroyed, arrive late or incomplete, or may contain
> viruses in transmission. The e mail and its contents (with or without
> referred errors) shall therefore not attach any liability on the originator
> or HCL or its affiliates. Views or opinions, if any, presented in this
> email are solely those of the author and may not necessarily reflect the
> views or opinions of HCL or its affiliates. Any form of reproduction,
> dissemination, copying, disclosure, modification, distribution and / or
> publication of this message without the prior written consent of authorized
> representative of HCL is strictly prohibited. If you have received this
> email in error please delete it and notify the sender immediately. Before
> opening any email and/or attachments, please check them for viruses and
> other defects.
> ________________________________
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to