Rex, I had a bit too much egg-nog while on the job too I guess.  I saw that 
*right* after I pressed Send....   at least we all had the right link!!!  

_____________________________________________________________________________________________________
Dave Jousma
AVP | Manager, Systems Engineering  

Fifth Third Bank  |  1830 East Paris Ave, SE  |  MD RSCB2H  |  Grand Rapids, MI 
49546
616.653.8429  |  fax: 616.653.2717


-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Pommier, Rex
Sent: Monday, December 23, 2019 2:29 PM
To: [email protected]
Subject: Re: LOGSTREAM sizing factors

**CAUTION EXTERNAL EMAIL**

**DO NOT open attachments or click on links from unknown senders or unexpected 
emails**

Dave,

Somewhere in the middle?  Lizette's first attempt was CISIZER, the second 
CFCISER, reality CFSIZER.  

Don't worry, Lizette, I do the same thing all the time.  :-)  You got it right 
where it counted - in the URL.

Rex

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Jousma, David
Sent: Monday, December 23, 2019 11:57 AM
To: [email protected]
Subject: [External] Re: LOGSTREAM sizing factors

I think you were right the first time Lizette!  A bit early for the egg-nog... 😊

https://www.ibm.com/support/pages/cfsizer


_____________________________________________________________________________________________________
Dave Jousma
AVP | Manager, Systems Engineering  

Fifth Third Bank  |  1830 East Paris Ave, SE  |  MD RSCB2H  |  Grand Rapids, MI 
49546
616.653.8429  |  fax: 616.653.2717


-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Lizette Koehler
Sent: Monday, December 23, 2019 12:53 PM
To: [email protected]
Subject: Re: LOGSTREAM sizing factors

**CAUTION EXTERNAL EMAIL**

**DO NOT open attachments or click on links from unknown senders or unexpected 
emails**

Sorry it should read CFCISER not CISIZER.  Had a finger check

Lizette


> -----Original Message-----
> From: IBM Mainframe Discussion List <[email protected]> On 
> Behalf Of Lizette Koehler
> Sent: Monday, December 23, 2019 10:42 AM
> To: [email protected]
> Subject: Re: LOGSTREAM sizing factors
> 
> Have you tried the CISIZER on     https://www.ibm.com/support/pages/cfsizer
> 
> 
> It may have some information for you on this process.
> 
> 
> 
> > -----Original Message-----
> > From: IBM Mainframe Discussion List <[email protected]> On 
> > Behalf Of Peter
> > Sent: Monday, December 23, 2019 9:25 AM
> > To: [email protected]
> > Subject: LOGSTREAM sizing factors
> >
> > Hello All,
> >
> >
> > We are going to deploy a zOS product which writes LOGSTREAM  on CF
> structure.
> > From the performance point of view what are all aspects i need to be 
> > aware for example dasd space for LOGSTREAM logs, storage sizing , CF 
> > memory sizing and we are expecting atleast 50 million transaction on
> production.
> > .
> >
> > Could you provide me an idea based on which i can size my LOGSTREAM
> >
> > Peter
> >
> > --------------------------------------------------------------------
> > -- For IBM-MAIN subscribe / signoff / archive access instructions, 
> > send email to [email protected] with the message: INFO 
> > IBM-MAIN
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send 
> email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN **CAUTION EXTERNAL 
EMAIL**

**DO NOT open attachments or click on links from unknown senders or unexpected 
emails**

This e-mail transmission contains information that is confidential and may be 
privileged.   It is intended only for the addressee(s) named above. If you 
receive this e-mail in error, please do not read, copy or disseminate it in any 
manner. If you are not the intended recipient, any disclosure, copying, 
distribution or use of the contents of this information is prohibited. Please 
reply to the message immediately by informing the sender that the message was 
misdirected. After replying, please erase it from your computer system. Your 
assistance in correcting this error is appreciated.


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

The information contained in this message is confidential, protected from 
disclosure and may be legally privileged.  If the reader of this message is not 
the intended recipient or an employee or agent responsible for delivering this 
message to the intended recipient, you are hereby notified that any disclosure, 
distribution, copying, or any action taken or action omitted in reliance on it, 
is strictly prohibited and may be unlawful.  If you have received this 
communication in error, please notify us immediately by replying to this 
message and destroy the material in its entirety, whether in electronic or hard 
copy format.  Thank you.


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN **CAUTION EXTERNAL 
EMAIL**

**DO NOT open attachments or click on links from unknown senders or unexpected 
emails**

This e-mail transmission contains information that is confidential and may be 
privileged.   It is intended only for the addressee(s) named above. If you 
receive this e-mail in error, please do not read, copy or disseminate it in any 
manner. If you are not the intended recipient, any disclosure, copying, 
distribution or use of the contents of this information is prohibited. Please 
reply to the message immediately by informing the sender that the message was 
misdirected. After replying, please erase it from your computer system. Your 
assistance in correcting this error is appreciated.


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to