For z/VM, you can definitely activate a new I/O configuration using the
ACTIVATE command. See

https://www.ibm.com/support/knowledgecenter/en/SSB27U_7.1.0/com.ibm.zvm.v710.hcpe2/rexxact.htm

I do not know if there are specific limitations for FCP


Mike








On Sun, 19 Jan 2020 at 07:17, Jake Anderson <[email protected]>
wrote:

> Hello
>
> Is it possible to define a set of FCP devices to a zVM dynamically without
> a POR.?
>
> Jake
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>


-- 
Mike Shorkend
[email protected]
www.shorkend.com
Tel: +972524208743
Fax: +97239772196

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN