Few options are

1. JES3 - if your shop uses JES3, update initdeck to make these devices
online and hot refresh JES3 or IPL.
2. AOM - if your shop uses AOM, update parms to bring those devices online
with AOM.
3. IODF - update IODF offline parm to NO. This require dynamic IODF update
4. Commndxx - update commndxx to bring required devices online.


My recommendation is to use commndxx. This method is easy to implement with
very minimum changes required. In future, its easy to find and maintain for
other system programmers.

Thanks,
Prashant


IBM Mainframe Discussion List <[email protected]> wrote on
26-03-2020 09:55:10:

> From: Peter <[email protected]>
> To: [email protected]
> Date: 26-03-2020 09:55
> Subject: [EXTERNAL] Tape devices not online during IPL
> Sent by: IBM Mainframe Discussion List <[email protected]>
>
> Hello
>
> Hope everyone is doing well and safe .
>
> When we IPL our system our Physical and virtual devices are not coming
> online automatically and everytime we need to issue VARY ONLINE command.
> Due to this our DFSMSrmm often throws intervention error message for
RETRY.
>
> I know COMMDxx parm can vary on it automatically during startup. Is it
> possible that I can modify it in IODF definition which can make it online
> automatically once the system loads ?
>
> What would be the best approach to this issue?
>
> Peter
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to