See interspersed:
-----Original Message----- From: IBM Mainframe Discussion List <[email protected]> On Behalf Of Richards, Robert B. Sent: Saturday, March 28, 2020 7:14 AM To: [email protected] Subject: Stunted JES2 spool volume and other questions [CAUTION: This Email is from outside the Organization. Do not click links or open attachments unless you trust the sender.] I tried to add a few spool volumes (z/OS 2.3) without paying attention to the TGSPACE value. My bad. Two were added, one was *stunted* and the last two were ignored. Now, I want to dynamically increase TGSPACE and SPOOLNUM and then add more spool volumes. Current TGSPACE=814,375 and 75% used --> <I do not believe there is any direct relationship between used TGSPACE and CHKPTSIZE. I believe Current SPOOLNUM=32 with 27 used and #28 stunted I need to know a few things: 1. How big do my checkpoints need to be if I plan to TRIPLE the TGSPACE to 2,443,200 and raise the SPOOLNUM to 64? * CKPT1 is a structure (150M and 78% used) --> <CFSIZER will provide the info> * CKPT2 is 200 cylinders on DASD --> <probably sufficient, but work backwards from the CFSIZER result 2. How do I get the rest of the track groups formatted on SPOOL #28 Plan is to $TSPOOLDEF the TGSPACE followed by the SPOOLNUM. If that goes well, handle #28 then $SPL(xxx), format several more spool volumes. --> I believe $SSPOOL (or one of the related commands) will handle the formatting once TGSPACE has been increased. Check the find manuals The only one in question here is the "stunted" volume. Worst case would be a drain and re-add. Any help/understanding would be appreciated. Bob ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected]<mailto:[email protected]> with the message: INFO IBM-MAIN ::DISCLAIMER:: ________________________________ The contents of this e-mail and any attachment(s) are confidential and intended for the named recipient(s) only. E-mail transmission is not guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or may contain viruses in transmission. The e mail and its contents (with or without referred errors) shall therefore not attach any liability on the originator or HCL or its affiliates. Views or opinions, if any, presented in this email are solely those of the author and may not necessarily reflect the views or opinions of HCL or its affiliates. Any form of reproduction, dissemination, copying, disclosure, modification, distribution and / or publication of this message without the prior written consent of authorized representative of HCL is strictly prohibited. If you have received this email in error please delete it and notify the sender immediately. Before opening any email and/or attachments, please check them for viruses and other defects. ________________________________ ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN
