It's hard to diagnose something like that without seeing the actual output.


--
Shmuel (Seymour J.) Metz
http://mason.gmu.edu/~smetz3

________________________________________
From: IBM Mainframe Discussion List [[email protected]] on behalf of 
Binyamin Dissen [[email protected]]
Sent: Wednesday, April 22, 2020 6:56 AM
To: [email protected]
Subject: Re: IPCS - RUNARRAY EXEC problem

The automatic LIST X is working, thus the command is valid.

The EXEC is not working properly.

On Tue, 21 Apr 2020 20:39:03 +0000 Seymour J Metz <[email protected]> wrote:

:>Did you run it without the ADDRESS keyword?
:>
:>
:>--
:>Shmuel (Seymour J.) Metz
:>http://mason.gmu.edu/~smetz3
:>
:>________________________________________
:>From: IBM Mainframe Discussion List [[email protected]] on behalf of 
Binyamin Dissen [[email protected]]
:>Sent: Tuesday, April 21, 2020 3:32 PM
:>To: [email protected]
:>Subject: Re: IPCS - RUNARRAY EXEC problem
:>
:>Typo when I copied it.
:>
:>The command is as you wrote and the result is as below.
:>
:>On Tue, 21 Apr 2020 19:07:48 +0000 Seymour J Metz <[email protected]> wrote:
:>
:>:>What is Xx?
:>:>
:>:>What output do you  get from
:>:>
:>:>RUNARRAY name EXEC((LIST X+8?+114 MULT(1) LENGTH(8)))
:>:>
:>:>
:>:>--
:>:>Shmuel (Seymour J.) Metz
:>:>http://mason.gmu.edu/~smetz3
:>:>
:>:>________________________________________
:>:>From: IBM Mainframe Discussion List [[email protected]] on behalf of 
Binyamin Dissen [[email protected]]
:>:>Sent: Tuesday, April 21, 2020 2:35 PM
:>:>To: [email protected]
:>:>Subject: IPCS - RUNARRAY EXEC problem
:>:>
:>:>Array define via
:>:>
:>:>EQ name X LENGTH(16) ENTRIES(1:20)
:>:>
:>:>Issuing
:>:>
:>:>RUNARRAY ADDR(name) EXEC((LIST Xx+8?+114 MULT(1) LENGTH(8)))
:>:>
:>:>The LIST command constantly displays the data from the first entry.
:>:>
:>:>Without the MULT operand it would display much more storage.
:>:>
:>:>The only example available is from RUNCHAIN in where the value of X is as
:>:>expected.
:>:>
:>:>What am I doing wrong>

--
Binyamin Dissen <[email protected]>
http://secure-web.cisco.com/1P8PPU3P_CJAnBU6EtyB2uLJvT8SiQM2BWSoVqIL141DNe_lLfXBwhXMauw_KXfrFASzF_mp3MWpbWaOs8X94HY1azz0Itp7oumBabwhXg6jAEc6Uasmvmhiwb3W7x6QMb2klXpSrUUvDbjdPhc2Vy2y7HZT39sTfeZIm2a809WdRJhdk_nUcJhqc60BBkRip0wcxMxAq7lp07SlrRL8GwgBNWPxVjm7s7luIG9af4oiJdXoANCUtl72S2pHoj7atfP1by8Q7ycE1JgUMRxeUEAnX2aZscqqoB871yXxjW5Y8ZNoI7FhnzL8FVSg-oWlFYN8VwLeSuZhRDrYJ0RXTWCjUyWdVL8JJByBgg473P5EGodxVL-u66q-bvslfSSQ-_d93ZOlTZl1HCcG6Dcmi1d3AnUaql7JhlcIM1_VKycTch0cLkKOjNcyFWURMfOQQ/http%3A%2F%2Fwww.dissensoftware.com

Director, Dissen Software, Bar & Grill - Israel


Should you use the mailblocks package and expect a response from me,
you should preauthorize the dissensoftware.com domain.

I very rarely bother responding to challenge/response systems,
especially those from irresponsible companies.

----------------------------------------------------------------------