From our NetMaster help screens:
--------------------- NETINFO : Browse 3274 Error Codes
-----------------------
3274 ERROR CODE ===> 210 (may be partial code)
Check Type: Machine Check
Description:
Keyboard type is not supported.
8421 Ind: Off Status Indicator displayed: X (\) 210
Recovery Action:
Ensure customising procedure specified that this keyboard type was
in
use on the controller.
Sense Codes:
Non-SNA :
SNA :
Applicable to: Type A terminal; feature.
-----Original Message-----
From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On
Behalf Of Rich Smrcina
Sent: May 3, 2006 19:25
To: [email protected]
Subject: Re: 3483 infowindow terminal
Try keyboard settings. There is either a setup screen or even dip
switches on the bottom
of the keyboard to indicate the type of keyboard. Try to set up the
second 3483 just like
the first one.
[EMAIL PROTECTED] wrote:
> I have one 3483-v infowindow terminal local non-sna attached to Z/VM
as t
> he
> master console (logged on as operator).
> This master terminal is connected coax to a 3274-41d controller.
> Works great!
>
> I have a second 3483-v infowindow terminal.
> I connect the coax to the same controller in any port and i get a
> x-210 error at the bottom left of the screen.
>
> I have tested the terminal by connecting it a Z/OS guest system under
VM.
>
> It worked fine.
> I tested all the ports in the 3274 with a 3471 infowindow.
> It works fine.
>
> I cannot see what i am doing wrong.
> Does anyone know what the x-210 error on the screen means?
>
> I can not find a book anywhere.
>
--
Rich Smrcina
VM Assist, Inc.
Main: (262)392-2026
Cell: (414)491-6001
Ans Service: (360)715-2467
rich.smrcina at vmassist.com
Catch the WAVV! http://www.wavv.org
WAVV 2007 - Green Bay, WI - May 18-22, 2007
The information transmitted is intended only for the person or entity to which
it is addressed and may contain confidential and/or privileged material. Any
review, retransmission, dissemination or other use of or taking of any action
in reliance upon, this information by persons or entities other than the
intended recipient or delegate is strictly prohibited. If you received this in
error, please contact the sender and delete the material from any computer.
The integrity and security of this message cannot by guaranteed on the
Internet. The Sender accepts no liability for the content of this e-mail, or
for the consequences of any actions taken on basis of the information provided.
The recipient should check this e-mail and any attachments for the presence of
viruses. The sender accepts no liability for any damage caused by any virus
transmitted by this e-mail. This disclaimer is the property of the TTC and
must not be altered or circumvented in any manner.