The IOCP was in fact incorrect. The person configuring it had the Z890 end shared and the zos end was not shared.
Once both ends were not shared, happiness reigned. Thanks Guys. _______________________ Jim Hughes 603-271-5586 "Impossible is just an opinion." =>-----Original Message----- =>From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On =>Behalf Of Dave Jones =>Sent: Saturday, May 13, 2006 2:09 PM =>To: [email protected] =>Subject: Re: ZVM 5.2 and Z890 and CTCA => =>Jim, make sure your IOCP is configured correctly and on line....looks lik= =>e =>the z/VM system doesn't see the CTC. => =>Hope this helps some. => =>DJ => =>Hughes, Jim - OIT wrote: => =>> We have a little problem with our new ZVM 5.2 system running on our new= => =>> Z890. =>> =>> We cannot get a real ctca defined and varied online to our ZOS system =>> running. =>> =>> I get a "path not operational" when a vary online path 62 to 6170 =>> =>> A QUERY CTCA ALL returns: =>> q ctca all =>> An active CTCA was not found. =>> A free CTCA was not found. =>> An offline CTCA was not found. =>> =>> What sort of thing should I be looking for to get over this hurdle??? =>> =>> Thanks. =>> =>> _______________________ =>> Jim Hughes =>> 603-271-5586 =>> "Impossible is just an opinion."