Hi Peter, that is what I will do.
Just talked to the hardware installer. No, he is not going to create a basic IOCP for us. But, he agreed to format the Shark for us to emulate 3390-3. He will also leave us a list on what CHPID the devices are connected to.
I have managed to create a standalone IPLable tape with ICKDSF and DDR before they took down the Hitachi. I would format the needed DASDs and restore the CP OWNED volumns - 4 of them. Then I will try to IPL VM. At that stage, I can use all 6 tape drives to restore the other 60 DASDs. Hopefully, I can re-IPL to bring up the full VM system.
Since CP would sense all the devices, I think I can use the DCPRDEVS utility to build a file of all real devices on the system. From there, I can build the final IOCS file and put it back to the service element using the IOCP command.
Thanks for your suggestions. Regards,
...Roland
[EMAIL PROTECTED] wrote:
[EMAIL PROTECTED] wrote:
Hi Roland,
Well, if the 2003-204 is anything like our 2003-225, then you have some
work to do. First, VM/ESA 2.3 should run just fine; we ran it for
several years before upgrading to z/VM 3.1. You can forget the old IOCP
from the Hitachi box, or any IOCP from another shop.
The problem here is that the CHPID numbers on the 2003 start at x'40'
and go up, with some skips (e.g. No x'4F'). Have your hardware guy cable
up the equipment the way it makes most sense to him, and create a basic
IOCP.
I assume you are using the internal dasd. As per Rob van der Heij, have
your hardware guy set them up as 3390-3. You will also get some small
volumes in this configuration, watch out for them. They can be useful
later, but will be a pain right now.
IPL standalone ICKDSF from your backup tapes and format all the volumes.
Use standalone DDR to restore your backups. Try IPLing your system
residence volume when you have finished the restores. If you are lucky,
and the customer used sensible VM configuration options, you should get
at least OPERATOR up, and maybe the whole system.
Peter
---- snipped ----
With best regards,
...Roland Chung
Senior Technical Specialist (S/390,VM/VSE,DB2/VSE&VM)
MAXC Consultants Inc.
Voice/Fax: 416-469-3280 (If busy, call: 416-469-2268)
197 Hastings Ave., Toronto, Ontario, Canada. M4L 2L6
** Life is short. Stop once in a while and smell the roses. **