See APAR VM64029 - PTF was just made available 7/6.   In summary, there is
a bug in SPXTAPE processing.

_______________________________________
James Vincent
Systems Engineering Consultant
Nationwide Services Co., Technology Solutions
Mainframe, z/VM and z/Linux Support
One Nationwide Plaza  3-20-13
Columbus OH 43215-2220   U.S.A
Voice: (614) 249-5547    Fax: (614) 677-7681
mailto:[EMAIL PROTECTED]


The IBM z/VM Operating System <[email protected]> wrote on 07/10/2006
09:31:21 AM:

> [email protected]
>
> We experienced our first CP abend in 6 years this weekend.  Our 2 month
> old ZVM 5.1 system running on a Z890 experienced an HPC010 abend.  It's
> not in the manual.
>
> What is the root cause?
>
> Thanks in advance.
>
> _______________________
> Jim Hughes
> 603-271-5586
> "Impossible is just an opinion."
> "Your career is what you're paid for, your calling is what you're made
> for."
> "We cannot solve our problems with the same thinking we used when we
> created them. Albert Einstein "