Hello, Yes, intend to have the DDR BACKUPs from the weekend, and two standalone utility tapes
available. Thanks for the CPVOL
LIST UNIT(addr) NOVERIFY. I forgot about that. Ed Martin From:
We are getting ready to migrate to a new
EMC DMX-1000 from a EMC Symmetrix 8350. Our current addresses are 740-7B6. We are generated for
740-7BF 128 devices, Devices 7B7-7BF are offline. The new addresses are 700-7CA. I am going to gen for 256
devices. The EMC will copy file disk as we run,
after the copy is done we will shut down, re-cable, Power_On_Reset
with a new IOCDS (A1). We will see all the
drives. We ipl z/VM from 792 at the moment, and
will have to change to 752 on the new system. 740 old is equal to 700 on new. Now that is way is suppose to work.
Suppose 752 does not IPL, what tools do we have to ensure that 752 is in fact 430RES? I have a Standalone system for VSE/ESA that
would give me DITTO. I could verify the name of the volume.
I have DDR tapes of the system. I could restore and ipl
from a different volume. Any other ideas that are easier and confirm
IPLable z/VM volumes? IDEAS WELCOME! Ed Martin |
- Re: New DASD questions cross post Edward M. Martin
- Re: New DASD questions cross post [EMAIL PROTECTED]