Alan:
I did not see anything in the trace, which follows, that seems
strange, but perhaps your eye will spot something. It almost seems as if
the LPR command is causing the LPD to ignore its normal settings. Is
there some FILTER option that would prevent this? I tried FILTER l as
you suggested, to no avail. I see there are other FILTER options, but
most (c,d,g,n,t, and v) are not explained in the TCP User's guide.
David Wakser
DTCLPX2034I -> Routine: Update_IntOpts
DTCLPX2032I .. Action (A) for option: TRACE
DTCLPX2032I .. Content of !wrk.mutul_opts string:
DTCLPX2032I .. PRINTER SYSTLAND HOST 192.168.168.239 TRACE
DTCLPX2034I <- Routine: Update_IntOpts
DTCLPX2032I .. Action (V) for option: FILTER
DTCLPX2032I .. Content of !wrk.opts string:
DTCLPX2032I .. l
DTCLPX2034I -> Routine: Proc_QuoteStr
DTCLPX2034I -> Argument(s):
l
DTCLPX2034I <- Routine: Proc_QuoteStr
DTCLPX2034I -> Routine: Validate_Token
DTCLPX2034I -> Argument(s): O FILTER M 1 1 0 l
DTCLPX2034I <- Routine: Validate_Token
DTCLPX2034I -> Routine: Update_IntOpts
DTCLPX2032I .. Action (A) for option: FILTER
DTCLPX2032I .. Content of !wrk.mutul_opts string:
DTCLPX2032I .. PRINTER SYSTLAND HOST 192.168.168.239 TRACE FILTER l
DTCLPX2034I <- Routine: Update_IntOpts
DTCLPX2034I <- Routine: Validate_Options
DTCLPX2034I -> Routine: Get_GlobalVarData
DTCLPX2036I .. Variable: PRINTER Value:
DTCLPX2036I .. Variable: PRTHOST Value:
DTCLPX2036I .. Variable: HOSTNAME Value:
DTCLPX2036I .. Variable: HOSTID Value:
DTCLPX2036I .. Variable: SERVER Value:
DTCLPX2036I .. Variable: LINKID Value:
DTCLPX2036I .. Variable: NODEID Value:
DTCLPX2036I .. Variable: LPRMODE Value:
DTCLPX2036I .. Variable: PRTNICK Value:
DTCLPX2036I .. Variable: PRTTAG Value:
DTCLPX2036I .. Variable: TRANSLATE Value:
DTCLPX2034I <- Routine: Get_GlobalVarData
DTCLPX2034I -> Routine: Resolve_Options
DTCLPX2037I LPRMODE (from: DEFAULT) resolved to: SYNCH
DTCLPX2037I PRINTER (from: CMDLINE) resolved to: SYSTLAND
DTCLPX2037I HOST (from: CMDLINE) resolved to: 192.168.168.239
DTCLPX2037I FILTER (from: CMDLINE) resolved to: l
DTCLPX2034I <- Routine: Resolve_Options
DTCLPX2034I -> Routine: Check_File_Input
DTCLPX2034I -> Routine: StateFile
DTCLPX2033I Command issued: STATE
DTCLPX2033I Command RC: 0
DTCLPX2033I Related data: PROFILE XEDIT A1 V 46 65
1 6/29/06 9:57:03
DTCLPX2034I <- Routine: StateFile
DTCLPX2037I FILE resolved to: PROFILE XEDIT A1
DTCLPX2034I <- Routine: Check_File_Input
DTCLPX2037I LPROPTS resolved to: HEADER PRINTER SYSTLAND HOST
192.168.168.239 TR
ACE FILTER l
LPR Level 510, Internal version ID: MT03713
DEFAULT translate table loaded: STANDARD TCPXLBIN
lpr to printer "SYSTLAND" at host "192.168.168.239"
Requesting TCP/IP service at 02/05/07 on 08:06:33
Granted TCP/IP service at 02/05/07 on 08:06:33
Resolving 192.168.168.239 at 02/05/07 on 08:06:33
Host 192.168.168.239 name resolved to 192.168.168.239 at 02/05/07 on
08:06:33
TCP/IP turned on.
Host "ZVM51IHS" Domain "LEONIA" TCPIP Service Machine TCPIP
Trying to open with local port UNSPECIFIED at 02/05/07 on 08:06:33
Connection open from local port 1229 to foreign port 515 at 02/05/07 on
08:06:33
MakeFileNames() entered
JobNumber =
Control file name is cfA923ZVM51IHS
Data file name is dfA923ZVM51IHS
Sending command 2 argument: "SYSTLAND"
Command successfully sent
Receiving ACK
Notification: Data delivered
ConnState: Open
ReceiveACK: TRUE for byte value 00
Byte size check starts on 02/05/07 at 08:06:33
Byte size check ends on 02/05/07 at 08:06:33
Send command starts on 02/05/07 at 08:06:33
Sending command 3 argument: "1657 dfA923ZVM51IHS"
Command successfully sent
Receiving ACK
Notification: Data delivered
ConnState: Open
ReceiveACK: TRUE for byte value 00
Send command ends on 02/05/07 at 08:06:33
Send data starts on 02/05/07 at 08:06:33
Send data ends on 02/05/07 at 08:06:33
Send ACK starts on 02/05/07 at 08:06:33
Sending ACK
ACK successfully sent
Send ACK ends on 02/05/07 at 08:06:33
Receiving ACK
Notification: Data delivered
ConnState: Open
ReceiveACK: TRUE for byte value 00
Data file sent.
Queuing control line "HZVM51IHS"
Queuing control line "PTS14"
Queuing control line "JPROFILE.XEDIT"
Queuing control line "CZVM51IHS.LEONIA"
Queuing control line "LTS14"
Queuing control line "ldfA923ZVM51IHS"
Queuing control line "UdfA923ZVM51IHS"
Queuing control line "NPROFILE.XEDIT"
Sending command 2 argument: "101 cfA923ZVM51IHS"
Command successfully sent
Receiving ACK
Notification: Data delivered
ConnState: Open
ReceiveACK: TRUE for byte value 00
Control data sent
Sending ACK
ACK successfully sent
Receiving ACK
Notification: Data delivered
ConnState: Open
ReceiveACK: TRUE for byte value 00
Control file sent.
Receiving ACK
Notification: Connection state changed
NewState: Receiving only
Notification: Connection state changed
NewState: Connection closing
Draining the connection.
Connection closed.
DTCLPX2034I <- Routine: Main
DTCLPX2034I -> Routine: LPR_Exit
DTCLPX2034I -> Routine: Proc_MsgRepos
DASD 0592 DETACHED
Ready; T=0.03/0.05 08:07:41
-----Original Message-----
From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On
Behalf Of Alan Altmark
Sent: Friday, February 02, 2007 9:24 AM
To: [email protected]
Subject: Re: LPR printing problem
On Friday, 02/02/2007 at 06:38 MST, "Wakser, David"
<[EMAIL PROTECTED]> wrote:
> How do I trace this? At the LPD or on VM?
Add the "TRACE" option to LPR to see what it is sending.