Frank,
Check the copy of SYSTEM NETID on the MAINT 490 minidisk. PUT2PROD will
first rebuild the CMS nucleus on the 490 disk and then copy the contents of
MAINT
490 to MAINT 190. If the SYSTEM NETID file on 490 is different than your
190 copy,
this could explain why you have to keep recovering the 190 version.
Cheers!
Mike
"Sikich, Frank
J."
<[EMAIL PROTECTED] To
ionalcity.com> [email protected]
Sent by: The IBM cc
z/VM Operating
System Subject
<[EMAIL PROTECTED] When applying a Service Corrective
ARK.EDU>
03/09/2007 12:08
PM
Please respond to
The IBM z/VM
Operating System
<[EMAIL PROTECTED]
ARK.EDU>
Has anyone come across when issuing the put2prod that the system netid file
on 190 disk is overwritten. I have had to recover this file twice now when
putting on a PTF. Is this file being copied from somewhere else that I
don't know about.
Thanks
Frank J. Sikich Jr.
EPS – MVS Support, but now working on z/VM
phone: 216.257.8012
email: [EMAIL PROTECTED] <mailto:[EMAIL PROTECTED]>