Hello
This is just 1/2 of a CTC connection but it's my first time with a single
control unit statement and 2 CSS's involved; I understand, I need to
define the CU in one CSS, then Modify it for the second.
I think the CSS number for the Modify is the second one I believe, I need
to DEF the devices in both CSS's.
Is that correct?
the chpid statements:
CHPID PATH=(CSS(1),16),PARTITION=((TPFPR430),(=)),SWITCH=64, X
PCHID=5F0,TYPE=FC
* *
CHPID PATH=(CSS(2),16),PARTITION=((TPFPR440),(=)),SWITCH=64, X
PCHID=441,TYPE=FC
the IOCP cu/dev statements:
* *
CNTLUNIT CUNUMBR=0504,PATH=((CSS(1),16),(CSS(2),16)), X
UNITADD=((04,004)),LINK=((CSS(1),1F),(CSS(2),21)), X
UNIT=FCTC
IODEVICE ADDRESS=(0504,004),CUNUMBR=(0504),UNIT=FCTC
the DynIO CP commands:
"CP DEF CU 0504 TY FICON_CTC UNITADD 04-07 LINK 1f PATH 16 CSS 1"
"CP MOD CU 0504 CSS 2 ADD_CSS_access PATH 16 LINK 21"
"CP DEF DEV 0504-0507 UNIT_A 04 CUNUMBR 0504 CSS 1 CTC EXT"
"CP DEF DEV 0504-0507 UNIT_A 04 CUNUMBR 0504 CSS 2 CTC EXT"