Hi Anne,

Linking to a first level minidisk will create a DASD device on your
second level system (1913 in your example below).  After you IPL your
second level system, do this:

VARY ON 1913 (in case it isn't already online)
ATTACH 1913 ESAMON (to attach it to userid ESAMON, substitute any other
userid of course).

Of course, don't try to write to that disk.........  :)

-Mike

-----Original Message-----
From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On
Behalf Of Anne Crabtree
Sent: Thursday, July 26, 2007 12:26 PM
To: [email protected]
Subject: z/vm 5.1 to 5.3 question


I have successfully installed, ipl'd, etc z/vm 5.3 second level on a
z/vm 5.1 system...  Am now trying to customize the USER DIRECT to match
current. (for instance, velocity software users!)  I do not have tape
drives at my disposal during the week.   I put links in the USER DIRECT
for VMTEST53 on first level, for instance:

LINK ESAMON 191 1913 RR

When I sign on to VMTEST53 prior to ipl and do 'Q V ALL', I can see
1913, but when I ipl, I can't access 1913...it doesn't exist.  I know
that I am missing part of the puzzle.  I want to copy the contents of
ESAMON 191 from first to second level.  Do I need a minidisk in VMTEST53
for 510RES (where ESAMON 191 disk is)? I was nervouse to refer to 510RES
at all even though it would be RR...

Anne D. Crabtree
System Programmer
WV Dept of Administration - OT
304-558-1494
Fax 304-558-1441