>I've renamed spool volumes several times, four or more years ago, but a
>force start was required. I don't recall whether it was VM/ESA or z/VM.
>I would recommend a spool backup before attempting it. And if it is for
>a production system, then schedule enough time to reload spool, if
>necessary.

A FORCE start will be required since the new CP_Owned list does not match
the CP_Owned list that was saved in the checkpoint area when you shut
down your system.

The spool files are restored from the warmstart area during IPL, so they
should be ok. You do risk losing information that was saved in the
checkpoint area that hasn't been processed by the time the difference
in the CP_Owned list is detected.

In any event, I agree that a spool file backup is a good idea before
attempting this change.

John Franciscovich
z/VM Development

Reply via email to