I am trying to send a simple text message to a SYSLOGD server. The
server is the one by Brian Wade that is on the IBM Downloads website. It
is nicely receiving messages from my linux servers that are on a
different network segment. The ERRNO 45: EOPNOTSUP is referenced once in
the TCP/IP Programmer's Reference. It says 'Operation not supported on
socket'. I am a novice plumber and even less experienced with network
programming. Can someone see something obviously wrong with this?
/Thomas Kern
/301-903-2211 (O)
/301-905-6427 (M)
/* 2SYSLOGD - Send argstring to SYSLOGD server */
parse arg datastring
'PIPE literal af_inet 514 205.254.145.36' ,
'| ip2socka' ,
'| var updpref' ,
'| spec 1-* c2x 1' ,
'| console'
updpref = x'0000000000000000' || updpref
'PIPE literal' updpref || datastring ,
'| udp 0 STAT LOCALIP 205.254.145.36' ,
'| console'
exit
2syslogd This is a test
00020202CDFE91240000000000000000
FPLTCQ1015E ERRNO 45: EOPNOTSUPP
FPLMSG003I ... Issued from stage 2 of pipeline 1
FPLMSG001I ... Running "udp 0 STAT LOCALIP 205.254.145.36"
FPLTCQ728I 0 messages sent
FPLTCQ728I 0 bytes sent
FPLTCQ728I 0 additional sends for RDW
FPLTCQ728I 0 additional sends for data
FPLTCQ728I 0 calls to wait for message
FPLTCQ728I 0 times an input record arrived during select
FPLTCQ728I 0 messages received
FPLTCQ728I 0 bytes received
FPLTCQ728I 2147483647 shortest message received
FPLTCQ728I 0 longest message received
FPLTCQ728I 0 read < 4K
FPLTCQ728I 0 read < 8K
FPLTCQ728I 0 read < 12K
FPLTCQ728I 0 read < 16K
FPLTCQ728I 0 read >= 16K
FPLTCQ728I 0 number of output records
FPLTCQ728I 0 additional receives for RDW
FPLTCQ728I 0 additional receives for data
FPLTCQ728I 0 additional records in frame
FPLTCQ728I 0 additional records in a message
FPLTCQ728I 0 sent < 4K
FPLTCQ728I 0 sent < 8K
FPLTCQ728I 0 sent < 12K
FPLTCQ728I 0 sent < 16K
FPLTCQ728I 0 sent >= 16K
FPLTCQ728I 4 calls to SMGIU