On Wednesday, 07/30/2008 at 03:22 EDT, Kris Buelens 
<[EMAIL PROTECTED]> wrote:
> The SET MACHINE 370 is gone indeed, I think with z series or even
> already since the later 9672's.
> To alleviate this, SET 370ACCOM ON was created to make CMS 370
> programs run in an XA machine, it knows how typical CMS programs
> behave.  There is a part in CMS and one in CP.
> Not even all old CMS programs could be helped this way, so it probably
> is not enough for an MVT or od MVS.

No, it is not enough for MVS, MVT, MFT, or even DOS/360.  Anything that 
runs DAT ON or that uses a problem-state PSW will fail. That pretty much 
rules out everything except CMS.

Look for details on the 370 Accomodation Facility in the CP Programming 
Services book.

Alan Altmark
z/VM Development
IBM Endicott

Reply via email to