I don't see any mistakes.  However
- For SYSTEM CONFIG:
  are you sure that DEFINE MDISK 991 39 120 53DRES points to the CF1
of the new system,
  and/or that the new system is IPLed with CF1 as its IPL "input"?
- For the CP directory
  You did mention you changed the directory source, but not that you placed
  the changed directory online on the RES of the new system, So
   DEFINE MDISK 991 511 175 53DRES #ACC 991 M
   DETACH 123
   DEFINE MDISK 123 0 END 53DRES
   DIRECTXA fn DIRECT M
   DET 123 991

2008/10/2 Martin, Terry R. (CMS/CTR) (CTR) <[EMAIL PROTECTED]>
>
> Hi
>
>
>
> I am trying to bring up my test LPAR which is a clone of another VM LPAR. 
> Before I did this I needed to update the SYSTEM CONFIG file and the USER 
> DIRECTORY to point to different RES, PAGE, SPOOL..etc.
>
>
>
> I attached the RES of the system I am trying to bring up to the working 
> system, I then issued a DEFINE MDISK 991 39 120 53DRES and then ACC 991 M.
>
>
>
> After I did this I was pointing to my SYSTEM CONFIG file on the TEST RES. I 
> made the changes to the SYSTEM CONFIG file and saved it.
>
>
>
> Next, I wanted to change the USER DIRECT to point to different RES and such. 
> I did another DEFINE MDISK 991 511 175 53DRES and then ACC 991 M.
>
>
>
> After I did this I was pointing to my USER DIRECT file on the TEST RES. I 
> made the changes to the USER DIRECT file and saved it.
>
>
>
> Next, I tried IPLing the TEST LPAR and I noticed that it was still looking at 
> the SYSTEM CONFIG without my changes from above as well the USER DIRECT 
> without my changes from above. It appears that the changes did not take.
>
>
>
> Where did I go wrong?
>
>
>
> Thank You,
>
>
>
> Terry Martin
>
> Lockheed Martin - Information Technology
>
> z/OS & z/VM Systems - Performance and Tuning
>
> Cell - 443 632-4191
>
> Work - 410 786-0386
>
> [EMAIL PROTECTED]
>
>


--
Kris Buelens,
IBM Belgium, VM customer support

Reply via email to