I would remove the portname from the vswitch definition it may be a
conflict with some one else who set it first 

-----Original Message-----
From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On
Behalf Of Mark Post
Sent: Tuesday, October 21, 2008 4:09 PM
To: [email protected]
Subject: Re: Connecting and testing a new pair of OSAs and new vswitch

>>> On 10/21/2008 at  3:55 PM, in message <[EMAIL PROTECTED]>, 
>>> Patrick
Spinler <[EMAIL PROTECTED]> wrote: 
-snip-
> qeth: received an IDX TERMINATE with cause code 0xf6
> qeth: sense data available on channel 0.0.8c00.
> qeth:  cstat 0x0
> qeth: irb: 00 c2 60 17  3f c9 90 38  0e 00 10 00  00 80 00 00
> qeth: irb: 01 02 00 00  00 00 00 00  00 00 00 00  00 00 00 00
> qeth: sense data: 02 00 00 00  00 00 00 00  00 00 00 00  00 00 00 00
> qeth: sense data: 00 00 00 00  00 00 00 00  00 00 00 00  00 00 00 00
> qeth: Initialization in hardsetup failed! rc=-5

This is your problem.  Now your problem is to find out what a 0xf6 IDX
terminate code means.  :(


Mark Post