Worked!
Thanks very much, Steve.

On Wed, Jan 14, 2009 at 2:24 PM, Steve Wilkins <[email protected]> wrote:

> I looked at the code real quick :-> it looks like you'll have to VARY OFF
> then back ON the 2 real volumes that back B28A & B28B to refresh the field
> being checked. Sorry.
>
> Do this with the VM/CP VARY command.
>
> Steve Wilkins
> IBM VM Development
> z/VM I/O Strategy
>
> [image: Inactive hide details for Mark Pace ---01/14/2009 01:59:18 PM---I
> just activated the license on our DS8100 for Point-in-time Co]Mark Pace
> ---01/14/2009 01:59:18 PM---I just activated the license on our DS8100 for
> Point-in-time Copy. But I'm having a problem.
>
>
> From:
> Mark Pace <[email protected]>
> To:
> [email protected]
> Date:
> 01/14/2009 01:59 PM
> Subject:
> Flashcopy
> ------------------------------
>
>
>
> I just activated the license on our DS8100 for Point-in-time Copy. But I'm
> having a problem.
> flashcopy b28a 0 b28b 0
> HCPNFC332E Invalid control unit type - B28A
> Ready(00332); T=0.01/0.01 13:52:00
>
> So I thought maybe something needed to change some definition in the
> DS8100. I searched and searched and found nothing. I searched IBMLink and
> did not find anything for the HCPNFC332E error. So on a whim I decided to
> try it on my z/VSE guest that is running under this VM.
> ixfp snap,syswk1:vsewk1
> AR+0015 IXFP23D SNAP FROM CUU=286 CYL='0000' TO CUU=284 CYL='0000'
> NCYL='0D0B'
> - REPLY 'YES' TO PROCEED
> 15 yes
> AR 0028 1H09I OPER INFO SYSXXX=286
> AR 0028 SUBSYSTEM STATUS CHANGE: FL-COPY RELATION ESTABLISHED
> AR 0028 1H09I OPER INFO SYSXXX=284
> AR 0028 SUBSYSTEM STATUS CHANGE: FL-COPY RELATION ESTABLISHED
> AR 0015 IXFP22I SNAP TO CUU= 284 STARTED AT 18:39:28 GMT 01/14/2009
> AR 0015 IXFP20I SNAP FUNCTION COMPLETED AT 18:39:28 GMT 01/14/2009
> AR 0015 1I40I READY
> AR 0028 1H09I OPER INFO SYSXXX=284
> AR 0028 SUBSYSTEM STATUS CHANGE: FL-COPY RELATION TERMINATED
> AR 0028 1H09I OPER INFO SYSXXX=286
> AR 0028 SUBSYSTEM STATUS CHANGE: FL-COPY RELATION TERMINATED
>
> Worked perfectly. So now I have to wonder why it does not work in z/VM.
>
> --
> Mark Pace
> Mainline Information Systems
> 1700 Summit Lake Drive
> Tallahassee, FL. 32317
>
>


-- 
Mark Pace
Mainline Information Systems
1700 Summit Lake Drive
Tallahassee, FL. 32317

Reply via email to