Adam, 
It looks like SERVICE is trying to service LE instead of LESFS.  There
are a couple of items in the PSP bucket that have to do with SFS, but
the descriptions aren't an exact match for this problem.  Did you read
all of the ZVM540 subsets and do what they said?

It's certainly possible to apply an RSU to a system with maintenance in
SFS.  I've done it for z/VM 5.4.0.  I didn't even customize the system
for TCP/IP first.  I used an ISFC link to read the RSU file from a
first-level system.

                                                       Dennis O'Brien

39,516
-----Original Message-----
From: The IBM z/VM Operating System [mailto:[email protected]] On
Behalf Of Adam Thornton
Sent: Tuesday, March 17, 2009 12:36
To: [email protected]
Subject: [IBMVM] Please tell me I did something stupid

I just installed a virgin z/VM 5.4 with all products on filepool  
rather than on minidisk.

I only tweaked it enough to get a TCPIP stack up and running so that I  
could FTP the RSU over to it, DETERSE it, and apply service.  I've  
done literally nothing else to the system.

00000 * * * Top of File * * *
00001  
************************************************************************
00002 ****             SERVICE               USERID:  
MAINT                ****
00003  
************************************************************************
00004 ****            Date: 03/17/09            Time:  
15:30:04            ****
00005  
************************************************************************
00006 ST:VMFSRV2195I SERVICE ALL RPTF0168
00007 ST:VMFSRV2760I SERVICE processing started
00008 ST:VMFSUI2760I VMFSUFIN processing started
00009 ST:VMFSUI2760I VMFSUFIN processing started for product 5VMLEN40%LE
00010 ST:VMFSET2760I VMFSETUP processing started for SERVP2P LE
00011 ST:VMFSET2204I Linking MAINT 4C4 as 4C4 with the link mode MR
00012 SV:HCPLNM107E MAINT 04C4 not linked; not in CP directory
00013 SV:VMFSET1965E The command, CP LINK MAINT 4C4 4C4 MR "", failed  
with
00014 SV:            return code 107
00015 ST:VMFSET2204I Linking MAINT 4C2 as 4C2 with the link mode MR
00016 SV:HCPLNM107E MAINT 04C2 not linked; not in CP directory
00017 SV:VMFSET1965E The command, CP LINK MAINT 4C2 4C2 MR "", failed  
with
00018 SV:            return code 107
00019 ST:VMFSET2204I Linking MAINT 4D2 as 4D2 with the link mode MR
00020 SV:HCPLNM107E MAINT 04D2 not linked; not in CP directory
00021 SV:VMFSET1965E The command, CP LINK MAINT 4D2 4D2 MR "", failed  
with
00022 SV:            return code 107
00023 ST:VMFSET2204I Linking MAINT 4A6 as 4A6 with the link mode MR
00024 SV:HCPLNM107E MAINT 04A6 not linked; not in CP directory
00025 SV:VMFSET1965E The command, CP LINK MAINT 4A6 4A6 MR "", failed  
with
00026 SV:            return code 107
00027 ST:VMFSET2204I Linking MAINT 4A4 as 4A4 with the link mode MR
00028 SV:HCPLNM107E MAINT 04A4 not linked; not in CP directory
00029 SV:VMFSET1965E The command, CP LINK MAINT 4A4 4A4 MR "", failed  
with
00030 SV:            return code 107
00031 ST:VMFSET2204I Linking MAINT 4A2 as 4A2 with the link mode MR
00032 SV:HCPLNM107E MAINT 04A2 not linked; not in CP directory
00033 SV:VMFSET1965E The command, CP LINK MAINT 4A2 4A2 MR "", failed  
with
00034 SV:            return code 107
00035 ST:VMFSET2204I Linking MAINT 4B2 as 4B2 with the link mode MR
00036 SV:HCPLNM107E MAINT 04B2 not linked; not in CP directory
00037 SV:VMFSET1965E The command, CP LINK MAINT 4B2 4B2 MR "", failed  
with
00038 SV:            return code 107
00039 ST:VMFSET2760I VMFSETUP processing completed unsuccessfully
00040 SV:VMFSUI1965E The command, VMFSETUP, failed with return code  
100 when
00041 SV:            issued with the argument(s): SERVP2P LE (LINK  
NOPROMPT
00042 SV:            RETAIN D
00043 ST:VMFSET2760I VMFSETUP processing started for DETACH LE
00044 ST:VMFSET2760I VMFSETUP processing completed successfully
00045 ST:VMFSUI2760I VMFSUFIN processing completed unsuccessfully
00046 ST:VMFSUI1211I An Initial Restart Record has been created for  
package
00047 ST:            RPTF0168 in the System-Level Restart Table
00048 SV:VMFSRV1965E The command, VMFSUFIN, failed with return code  
100 when
00049 SV:            issued with the argument(s): ALL ( NOPROMPT RSUENV
00050 SV:            RPTF0168
00051 WN:VMFSRV2310W Service restart file, SERVICE $RESTART A, has  
been created
00052 WN:            due to errors. Correct the errors, and restart  
SERVICE
00053 WN:            using the following command:
00054 WN:            SERVICE RESTART RPTF0168
00055 ST:VMFSRV2760I SERVICE processing completed unsuccessfully




Someone please say "Adam, you're an idiot, you obviously forgot the  
<somethingorother>" and not "Oh!  Wow.  Yeah, you're right!  The RSU  
doesn't actually work on filepool systems."

Reinstalling the system from scratch--while not technically  
challenging--*will* tick me off.

Adam

Reply via email to