still pretty sweet that after all these years (decades!) CP will still initialize to a 3215! Albeit a virtual one.
David

-------- Original Message --------
Subject: Re: [IBMVM] Problems with IPLing a SECOND LEVEL z/VM 5.3
From: Michael Coffin <[email protected]>
Date: Thu, April 09, 2009 1:51 pm
To: [email protected]

Yup, that's definitely it.  Do:
 
CP TERM CONMODE 3270
IPL 1000 CLEAR LOADPARM 009
 
that will  bring up the standalone loader using the virtual machine's console at 009, in 3270 mode.
 
On the standalone loader type:
cons=009
 
in the parms section BEFORE pressing PF10.
 
-Mike
-----Original Message-----
From: The IBM z/VM Operating System [mailto:[email protected]] On Behalf Of Bob Bates
Sent: Thursday, April 09, 2009 1:45 PM
To: [email protected]
Subject: Re: Problems with IPLing a SECOND LEVEL z/VM 5.3

Remember to do TERM CONMODE 3270 before the IPL?
 
Also, you may need to put the cons=0009 on the load screen (assuming the address of your console is 0009)
 
Bob Bates
Enterprise Hosting Services

w. (469)892-6660
c. (214) 907-5071
“This message may contain confidential and/or privileged information.  If you are not the addressee or authorized to receive this for the addressee, you must not use, copy, disclose, or take any action based on this message or any information herein.  If you have received this message in error, please advise the sender immediately by reply e-mail and delete this message.  Thank you for your cooperation."

 


From: The IBM z/VM Operating System [mailto:[email protected]] On Behalf Of Martin, Terry R. (LOCKHEED MARTIN Performance Engineering/CTR) (CTR)
Sent: Thursday, April 09, 2009 12:38 PM
To: [email protected]
Subject: Problems with IPLing a SECOND LEVEL z/VM 5.3

Hi
 
I am taking my first crack at building a 2nd level z/VM under my 1st level z/VM. I tried IPLing the 2nd level and I am receiving the following:
 
 
13:20:27 Start ((Warm|Force|COLD|CLEAN) (DRain) (DIsable)  (NODIRect)
13:20:27       (NOAUTOlog)) or (SHUTDOWN)                            
H HCPSED6013A A CP read is pending.             
 
At this point I cannot enter anything in the console.        
 
A little background on how I built this. The 2nd level is a copy of my 1st level with any needed changes to the SYSTEM CONFIG and Directory files. The RES and Spool are copies from my first level.  Below is a copy of my SECLVL user directory entry:
 
USER SECLVL SECLVL 500M 500M BCDEFG
MACHINE ESA 2                     
OPTION TODENABLE                  
IPL CMS                           
CONSOLE 0009 3215 T OPERATOR      
SPOOL 000C READER A               
SPOOL 000D PUNCH A                
SPOOL 000E PRINTER A              
LINK MAINT 0190 0190 RR           
LINK MAINT 019D 019D RR           
LINK MAINT 019E 019E RR           
MDISK 191  3390 1 200 53DW01 MR   
MDISK 1000 3390 0 END 53DRES MR   
MDISK 12F1 3390 0 END 53DPAG MR   
MDISK 12F2 3390 0 END 53DSPL MR   
 
Now the examples in the book ’z/VM Running Guest Operating Systems’  are using one disk broken down into multiple mdisks for RES, PAGE, and SPOOL. I just decided to use my copy of the first level and make these full pack mdisks as you see in the user directory. Will this approach work? Or am I missing something.              
 
Thank You,
 
Terry Martin
Lockheed Martin - Information Technology
z/OS & z/VM Systems - Performance and Tuning
Cell - 443 632-4191
Work - 410 786-0386
 
  • ... Martin, Terry R. (LOCKHEED MARTIN Performance Engineering/CTR) (CTR)
    • ... Bob Bates
      • ... Michael Coffin
    • ... Wandschneider, Scott
    • ... Wandschneider, Scott
    • ... David Kreuter
      • ... Kris Buelens
        • ... Schuh, Richard
          • ... Kris Buelens
            • ... Schuh, Richard
              • ... Kris Buelens
                • ... Schuh, Richard
                • ... James Stracka (DHL US)
                • ... Schuh, Richard
              • ... Rich Greenberg
        • ... Martin, Terry R. (LOCKHEED MARTIN Performance Engineering/CTR) (CTR)

Reply via email to