What's important is what is in the active IOCDS on your z800.  Assuming 

that your z/OS guests do not have permissions to update the real IOCDS 

then it doesn't matter to you what is in their z/OS HCD config (all 
they'll really care about is that it agrees with what's in their virtual 

machine definition).

Brian Nielsen


On Wed, 1 Jul 2009 08:47:05 -0500, Vince Getgood 
<[email protected]> wrote:

>Hi all,
>I've just been making a Visio diagram of out I/O config on some old 
>hardware (z800), which runs two z/OS guests under VM (5.4)
>
>I dicovered that, although the VM IOCP has channels to my DASD system as
 
>FC (FICON) the z/OS IOCP has them defined as CNC (ESCON).
>
>So what "speed" am I going to get on a z/OS I/O, ESCON or FICON? 
>
>I'm assuming VM does something clever, like ignore what z/OS says?
>
>TIA

Reply via email to