On Monday, 09/21/2009 at 10:48 EDT, "Martin, Terry R. (CMS/CTR) (CTR)" 
<[email protected]> wrote:

> I did my links but when I tried to IPL 490 I received the following any 
ideas?

> 10:42:51 CP I 490               
> 
> RACFVM CMS XA Rel 14 03/19/2002 
> 
>      6 *-* 'SYNONYM SYN'        
> 
>        +++ RC(-3) +++           
> 
> Ready; T=0.01/0.01 10:42:51     

It's normal.  "RACFVM CMS XA Rel 14" should be treated more like a custom 
runtime environment for RACF (which it is) rather than "CMS".  No Pipes, 
either.

Alan Altmark
z/VM Development
IBM Endicott