Thank you for verifying my assumption.
Thank you, Scott From: The IBM z/VM Operating System [mailto:[email protected]] On Behalf Of Kris Buelens Sent: Monday, November 16, 2009 12:02 PM To: [email protected] Subject: Re: Question on MODIFY COMMAND No, he won't. But, with CP class A, he can issue SET PRIVCLASS * +S. You your change is only safe to avoid accidental FORCEs or SHUTDOWNs 2009/11/16 Wandschneider, Scott <[email protected]> If I change SHUTDOWN and FORCE with the following: MODIFY COMMAND SHUTDOWN PRIVCLASS S MODIFY COMMAND FORCE PRIVCLASS S ...and OPER1 does not have class S but does have class A, can OPER1 still successfully issue SHUTDOWN or FORCE? Thank you, Scott R Wandschneider Senior Systems Programmer|| Infocrossing, a Wipro Company || 11707 Miracle Hills Drive, Omaha, NE, 68154-4457|| ': 402.963.8905 || Ë:847.849.7223 || : [email protected] **Think Green - Please print responsibly** -- Kris Buelens, IBM Belgium, VM customer support