> -----Original Message-----
> From: The IBM z/VM Operating System 
> [mailto:[email protected]] On Behalf Of Gregg
> Sent: Wednesday, December 16, 2009 11:25 AM
> To: [email protected]
> Subject: System Free Storage
> 
> We've an application that gets HCPLIM6007I, and eventually 
> 6008E or 6009E
> Short of logging off/on, is there a way for the logon to advise CP
> they nolonger need it?
> It seems to survive a CP IPL or CP SYSTEM CLEAR...
> The disconnected machines, don't appear to be doing any of the items
> mentioned under User Response in HCP6007I, but I do not have access to
> the source and they maybe "issuing CP commands that consume free
> storage"... aside from getting the source and trying any, is there any
> way to know ahead of time what CP commands those might be?
> 
> 
> --
> Gregg Reed

Just out of curiousity, have you tried doing a CP DEFINE STORAGE?

--