Hi, 

I have an error, I'll correct this and that's OK.

profile exec zvse42

&CONTROL OFF                             
CP SET RUN ON                            
CP COUPLE 840 TCPIP 841                  
CP COUPLE 841 TCPIP 840                  
CP TERM CON 3270 BREAKIN GUEST           
CP SET QUICKDSP VSEESA5 ON               
CP IPL 256 LOADPARM .....                
EXIT                                   

profile exec TCPIP
&CONTROL OFF                             
CP SET RUN ON                            
CP COUPLE 840 ZVSE42 841                  
CP COUPLE 841 ZVSE42 840                  


profile TCPIP (user TCPMAINT)

'CP COUPLE 840 ZVSE42 841'   
'CP COUPLE 841 ZVSE42 840'   

The other thing.

DOWN TCPIP in a ZVM.
START TCPIP in a ZVM.

In TCPIP for zVSE:
MSG TCPSTART,data=stop
MSG TCPSTART,data=start

The message in a system console:
F7 0168 0003: IPL491I CTCA link ZVM_TCPIP started on devices 0840 - > 
F7 0168 0841 as 192.168.96.1                                          


That's all folks.

Thank you very much for all.


Best Regards,


Mario Izaguirre
Mainframe System Programmer
Barcelona, Spain
-----Mensaje original-----
De: The IBM z/VM Operating System [mailto:[email protected]] En nombre de 
Ivica Brodaric
Enviado el: miƩrcoles, 10 de marzo de 2010 12:23
Para: [email protected]
Asunto: Re: TCPIP-CTC Error

Did you COUPLE send port with receive port of the other side, ie TCPIP
840 -> ZVSE42 841, TCPIP 841 <- ZVSE42 840?

Ivica