OK, problem solved....it was a bad DCSS file. I purged it, and now the module starts and runs as it should. I'm working now with the vendor to see how I can recreate the DCSS.
Thanks again. DJ ----- Original Message ----- From: Alan Altmark <[email protected]> To: [email protected] Subject: Re: CP soft abend code NTF001 Date: Fri, 23 Jul 2010 11:30:48 -0400 > On Friday, 07/23/2010 at 10:29 EDT, dave > <[email protected]> wrote: > > > I have a CMS module, coded in assembler, that, when run, > > causes a NTF001 soft abend when run from one virtual > > machine, but when run from another virtual machine it > > runs normally. > > > > Both virtual machines are set to XA, both have the same > > amount of virtual storage defined, both have the same > > set of options set, and NUCXMAP shows the same nucleus > > contents in both. What have I overlooked? > > It doesn't have anything to do with CMS, per se. Would it > help to know that HCPNTF is involved in locating and > reading a DCSS or NSS? That would seem to lead me to the > conclusion that something is changing a spool file or > queue without proper serialization. > > Alan Altmark > z/VM Development > IBM Endicott