That's then to confuse everyone 0 and O, who can tell the difference unless
having a very good font, and even then.

If you change, change it better, not more work
Why not 54TRES, 54TW01 etc

2010/9/29 George Henke/NYLIC <george_he...@newyorklife.com>

>
> As always, Alan, ty for the good advice.
>
> I have renamed with CPFMTXA the 2nd Level disks to 54O(Oh)RES, 54O(Oh)W01,
> adn 54O(Oh)W02 and will copy the 2 page and 2 spool disks just for
> simplicity, neatness counts.
>
>
>
>  *Alan Altmark <alan_altm...@us.ibm.com>*
> Sent by: The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU>
>
> 09/28/2010 11:59 PM
>  Please respond to
> The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU>
>
>   To
> IBMVM@LISTSERV.UARK.EDU
> cc
>   Subject
> Re: Applying Maintenance - Best Practice
>
>
>
>
> On Tuesday, 09/28/2010 at 04:35 EDT, George Henke/NYLIC
> <george_he...@newyorklife.com> wrote:
> > Can I bring up z/VM Level 2 wiith the same cloned volser's, directory,
> and CF
> > parm disks as z/VM Level 1 as long as I  point to the cloned 540RES and
> FORCE
> > start when I IPL?
> >
> > I have  DDRed my 540RES, 540W01, 540W02, Level 1 disks to separate disks
> and
> > they now have the same volsers.
> >
> > Do I need to also DDR the PAG and SPL disks or can I just FORCE start
> with
> > empty disks.
>
> You need to copy the disks or CPFMTXA them.
>
> > The directory and CF parm disks came over with 540RES.  Since the names
> have
> > not changed Is their "referential integrity" still intact?
>
> Unless you follow my previously posted advice about using OFFLINE_AT_IPL,
> duplicate volids create the potential for bad things to happen.  I suggest
> you change the volsers (which means changing SYSTEM CONFIG and USER
> DIRECT).
>
> Alan Altmark
>
> z/VM and Linux on System z Consultant
> IBM System Lab Services and Training
> ibm.com/systems/services/labservices
> office: 607.429.3323
> alan_altm...@us.ibm.com
> IBM Endicott
>
>


-- 
Kris Buelens,
IBM Belgium, VM customer support

Reply via email to