Sorry, it is not possible. z/VM does not support dynamically adding xstore. You need to define more initial xstore, shut down, deactivate and active the LPAR, then IPL. And don't bother defining reserved expanded storage in the image profile.
On Mon, Oct 11, 2010 at 10:13 AM, Tomas Norberg <[email protected]> wrote: > > Hi, > > Is there a way to add expanded storage dynamically to a running system > without an IPL, like the SET STORAGE command for central storage? > > In our HMC image profile for a test system we have defined expanded storage > as Initial 1024 MB and reserved 1024MB. But we have not found a command to > activate the extra expanded storage in VM. > > q xstor: > > XSTORE= 2048M online= 1024M > XSTORE= 1024M userid= SYSTEM usage= 55% retained= 0M pending= 0M > XSTORE MDC min=0M, max=1024M, usage=55% > XSTORE= 1024M userid= (none) max. attach= 1024M > > Thanks > > Tomas Norberg > -- Bruce Hayden z/VM and Linux on System z ATS IBM, Endicott, NY